Annual Maintenance 

*Order filters by calling 1-800-752-5582 or buy online at www.premierH2o.com

• 

Stage 1 - Sediment Filter (part #: 104017) 

• 

Stage 2 - Carbon Block Filter (part #: 101009 -White end caps)

• 

Stage 4 - VOC Carbon Block Filter (part #: 101013 -Blue end caps)

• 

1/4 Cup of common household bleach.

NOTICE: Sanitizing of unit is recommended. 

Step 1:  Perform steps 1 through 3 in the Six Month System Maintenance (Page 13).
Step 2:   

For more leverage you may leave the RO module attached to wall of cabinet.  If you are 

unable to access the module while it hangs, remove it prior to changing filters.   Starting with 

the closest housing (Stage 1), remove it by turning it clockwise, empty water, then discard 

filter.  Continue on to the 2

nd 

(Stage 2) and 3

rd

 (Stage 4) housings. 

NOTICE: If not sanitizing the system, skip to step 9

Step 3:    Remove the RO membrane from its housing and rest in a clean sanitary place. (Refer to 

“Membrane Replacement” section  on page 15 for directions on removing the membrane). 

Replace empty membrane housing onto unit.

Step 4:   Leaving the filters out, replace stage 2 and 4 empty filter housings (hand tight) onto 

unit.  Measure & pour 1/4 cup of of common household bleach into the 1st filter housing 

(Stage 1) and hand tighten onto unit.

DANGER

!

IF BLEACH GETS IN EYES: Hold eye open and rinse slowly and gently with water 

for 15 - 20 minutes. Remove contact lenses if present, after the first 5 minutes, then 
continue rinsing eye. Call a poison control center or doctor for treatment advice. 

Step 4:   With the RO faucet in the closed position turn on the incoming water supply to the 

system by turning the adapt-a-valve counter clockwise.  Let the unit fill with water 

(approximately 8 minutes) allowing the bleach to dilute. 

Step 5:  Let the system sit idle for 1 minute

Step 6:  Drain the system completely

Step 7:   Let the system fill again (approximately 8 minutes) and sit idle for 10 minutes before 

draining the system again.

Step 8:   Turn off the incoming water at the adapt-a-valve and open the faucet to make sure all 

the water has been drained

Step 7:   Open the membrane vessel and insert the RO membrane back into the manifold while 

making sure not to kink the O-rings. Tighten the membrane housing back on the RO unit 

(Refer to “Membrane Replacement” on Page 15 for details).

Step 8:  Remove filter housings Stage 1, 2 and 4 and empty of water.

NOTICE:  Before re-installing the filter bowls back on to the system , check O-rings to make sure 

they are still in place and lubricate with water soluble lubricant.

Step 9:   Insert the new sediment filter (cloth like appearance) into the 1st filter housing which is the one 

closest to the side with tubing connections and re-install housing.

Step 10:   Insert the new Carbon Block filter (White End Caps) into the middle housing and re-install 

housing.   

Step 11:   Insert the new VOC Carbon Block filter (Blue End Caps) into the 3rd filter housing (Stage 4) 

which is the one farthest from the side with tubing connections and re-install housing.

SANIT

ATION STEPS

Содержание Premier WP4V-50

Страница 1: ...installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www...

Страница 2: ...RO membrane This semi permeable membrane will take out TDS Sodium and a wide range of contaminants such as Chromium Arsenic Copper Lead as well as Cysts such as Giardia and Cryptosporidium and much m...

Страница 3: ...Installation 10 Drain Saddle Tube Connection 10 Reverse Osmosis Module Mounting 11 Green Tube Connection 11 Tank Elbow Installation 11 Connect Blue Tube from TANK Port on RO Module to the Tank 11 Con...

Страница 4: ...Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 1...

Страница 5: ...1 104017 Sediment Filter 10 Inch 5M 4 ALT 1 560016 RO Membrane 35GPD 4 1 560018 RO Membrane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Mem...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...b and Install Spout Figure C This RO faucet is equipped with quick connect fittings for easy tube installation To connect tubes simply push them firmly into their corresponding fitting on the RO fauce...

Страница 8: ...ur faucet will have a good seal Disassembling your faucet is never recommended as this could void your warranty If it is necessary to remove the fitting at the end of the toggle bolt you must follow t...

Страница 9: ...Hot water will severely damage your system 3 8 Configuration With Brass Fittings Insert White Washer 1 2 Configuration Without Brass Fittings White Washer Hot Supply Cold Supply Hot Supply Cold Supply...

Страница 10: ...e second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit...

Страница 11: ...quick connect fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Connect red faucet tube Green Tube Connection Step 14 Locate green tube attached to t...

Страница 12: ...aucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Страница 13: ...pty to depressurize before attempting to remove filter housings Open the RO Faucet and allow water to drain from the tank until it is completely empty Insert the new Carbon Block filter White End Caps...

Страница 14: ...inutes then continue rinsing eye Call a poison control center or doctor for treatment advice Step 4 With the RO faucet in the closed position turn on the incoming water supply to the system by turning...

Страница 15: ...ntil it stops Follow the green tube away from the RO system to find the adapt a valve Step 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 3 Remove the ho...

Страница 16: ...uge is recommended Check Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO Open the RO Faucet and allow...

Страница 17: ...or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High wa...

Страница 18: ...omplete list of VOC s Recovery 13 7 Daily Production Rate 9 86 GPD Efficiency 6 8 Depending on water chemistry water temperature and water pressure Premier s R O Systems production and performance wil...

Страница 19: ...ne where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the util...

Страница 20: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 21: ...urchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage VOC Block 1 year 3rd...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without 9 adequate disinf...

Отзывы: