TROUBLE SHOOTING

Problem   

 Cause    Solution

1. Low/Slow Production  

Low Water Pressure 

 

Assure a minimum of 40 psi incoming water pressure.

 

 

 

 

 

 

 

Premier sells a booster pump if home water pressure is

 

 

 

 

 

 

 

low.  Maker sure water supply is turned on and Adapta 

 

 

 

 

 

 

 

Valve is all the way open

 

 

 

Crimps in tubing 

 

Check tubing and straighten or replace as necessary.

 

 

 

Clogged pre-filters 

 

Replace pre-filters.

 

 

 

Fouled membrane 

 

Replace membrane and clean flow restrictor.

2. Milky colored Water   

Air in system   

 

Air in the system is a normal occurrence with initial start 

 

 

 

 

 

 

 

up of the RO system.  This milky look will disappear 

 

 

 

 

 

 

 

during normal use within 1-2 weeks.  If condition reoccurs

 

 

 

 

 

 

 

after filter change, drain tank 1 to 2 times.

3. Water constantly  

 

Low water pressure 

 

See #1 Above

running/unit will not

shut off 

 

 

Fouled membrane 

 

Replace membrane

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does not

 

 

 

 

 

 

 

exceed 100psi. A pressure relief valve may be necessary.

 

 

 

High air pressure in tank 

Empty storage tank of water. Set tank air pressure to 5

 

 

     psi. 

See 

Page 

16.

4. Noise from faucet or drain 

Air gap faucet   

 

Inherent sound with air-gap faucets.

 

 

 

Location of drain saddle  

See diagram for proper location of drain saddle. 

 

 

 

Higher capacity membrane 

Normal with high capacity membrane

 

 

 

High water pressure 

 

Check incoming water pressure to make sure it does not

 

 

 

 

 

 

 

exceed 100 psi.  A presser relief valve may be necessary. 

 

5. Faucet leaks from 

 

Crimp or loop in drain line 

Straighten black 3/8 drain tube.  Cut off any excess tubing

the air gap feature   

 

Drain tube clogged/restricted 

Caused from dishwasher or garbage disposal.

 

 

 

 

 

 

 

Disconnect the 3/8” black tube at the drain, clean the 3/8”

 

 

 

 

 

 

 

black tube out with a wire, then reconnect.  

6. Small amount of water in  

System just starting up   

Normally it takes 3-6 hours to fill tank.  Note: Low water

storage tank 

 

 

 

 

 

 

pressure and/or temperature can drastically reduce

 

 

     production 

rate.

 

 

 

Low water pressure 

 

See #1 Above

 

 

 

Too much air in tank 

 

Add air if below 5 psi and bleed if above 5 psi. Check 

 

 

 

 

 

 

 

only when tank is empty of water.  See Page 16.

   

 

7. Water leaks from the   

Not properly tightened.   

Tighten the bowl

filter housing 

 

 

Missing or kinked O-ring  

Turn off the water supply.  Release the pressure, remove 

 

 

 

 

 

 

 

bowl and replace the O-ring.  (p/n 113043). Make sure    

 

 

 

 

 

 

 

the O-ring is seated in the filter bowl properly before 

 

 

 

 

 

 

 

reinstalling the filter bowl.

 

 

 

     

Содержание Premier WP4V-50

Страница 1: ...installation Your failure to follow any attached instructions or operating parameters may lead to the product s failure Watts Premier 8716 W Ludlow Drive Suite 1 Peoria AZ 85381 Phone 800 752 5582 www...

Страница 2: ...RO membrane This semi permeable membrane will take out TDS Sodium and a wide range of contaminants such as Chromium Arsenic Copper Lead as well as Cysts such as Giardia and Cryptosporidium and much m...

Страница 3: ...Installation 10 Drain Saddle Tube Connection 10 Reverse Osmosis Module Mounting 11 Green Tube Connection 11 Tank Elbow Installation 11 Connect Blue Tube from TANK Port on RO Module to the Tank 11 Con...

Страница 4: ...Operating Pressure Maximum 100 psi 7 0 kg cm2 Minimum 40 psi 2 80 kg cm2 pH Parameters Maximum 11 Minimum 2 Iron Maximum 0 2 ppm TDS Total Dissolved Solids 1800 ppm Turbidity 5 NTU Hardness Maximum 1...

Страница 5: ...1 104017 Sediment Filter 10 Inch 5M 4 ALT 1 560016 RO Membrane 35GPD 4 1 560018 RO Membrane 50GPD 5 3 113018 Filter Bowl 6 1 113035 Membrane Vessel 7 3 113041 O Ring Filter Bowl 8 1 113045 O Ring Mem...

Страница 6: ...hen drilling Watts accepts no responsibility for damage resulting from the installation of faucet Diamond tip bit recommended Marble Counter top We recommend contacting a qualified contractor for dril...

Страница 7: ...b and Install Spout Figure C This RO faucet is equipped with quick connect fittings for easy tube installation To connect tubes simply push them firmly into their corresponding fitting on the RO fauce...

Страница 8: ...ur faucet will have a good seal Disassembling your faucet is never recommended as this could void your warranty If it is necessary to remove the fitting at the end of the toggle bolt you must follow t...

Страница 9: ...Hot water will severely damage your system 3 8 Configuration With Brass Fittings Insert White Washer 1 2 Configuration Without Brass Fittings White Washer Hot Supply Cold Supply Hot Supply Cold Supply...

Страница 10: ...e second drain Installation of the drain saddle near a garbage disposal may cause the drain line to plug If no other installation of drain line is available Premier offers drain line installation kit...

Страница 11: ...quick connect fitting on the RO Manifold Make sure the tube is pushed in all the way to the tube stop See Picture Connect red faucet tube Green Tube Connection Step 14 Locate green tube attached to t...

Страница 12: ...aucet to flush the tank completely You will know that the tank is empty when the flow rate from the RO faucet is down to a trickle Repeat this step two more times The fourth tank can be used for drink...

Страница 13: ...pty to depressurize before attempting to remove filter housings Open the RO Faucet and allow water to drain from the tank until it is completely empty Insert the new Carbon Block filter White End Caps...

Страница 14: ...inutes then continue rinsing eye Call a poison control center or doctor for treatment advice Step 4 With the RO faucet in the closed position turn on the incoming water supply to the system by turning...

Страница 15: ...ntil it stops Follow the green tube away from the RO system to find the adapt a valve Step 2 Open the RO Faucet and allow water to drain from the tank until it is completely empty Step 3 Remove the ho...

Страница 16: ...uge is recommended Check Air Pressure in the Tank Important Step 3 Check air pressure only when tank is empty of water Step 1 Turn off the incoming water supply to the RO Open the RO Faucet and allow...

Страница 17: ...or drain Air gap faucet Inherent sound with air gap faucets Location of drain saddle See diagram for proper location of drain saddle Higher capacity membrane Normal with high capacity membrane High wa...

Страница 18: ...omplete list of VOC s Recovery 13 7 Daily Production Rate 9 86 GPD Efficiency 6 8 Depending on water chemistry water temperature and water pressure Premier s R O Systems production and performance wil...

Страница 19: ...ne where it does convert trivalent arsenic to pentavalent arsenic may not convert all the trivalent arsenic in to pentavalent arsenic If you get your water from a public water utility contact the util...

Страница 20: ...ONITRILE 98 0 024 0 0006 DICHLOROACETONITRILE 98 0 0096 0 0002 TRICHLOROACETONITRILE 98 0 015 0 0003 HALOKETONES HK 1 1 DICHLORO 2 PROPANONE 99 0 0072 0 0001 1 1 1 TRICHLORO 2 PROPANONE 96 0 0082 0 00...

Страница 21: ...urchase __________ Date of Install ___________ Installed by __________________ Serial No _____________________ Date 1st stage Sediment 6 months 2nd stage Carbon 6 months 4th stage VOC Block 1 year 3rd...

Страница 22: ...exceed 105 degrees F 40 degrees C 7 Incoming TDS Total Dissolved Solids not to exceed 1800 ppm 8 Do not use with water that is micro biologically unsafe or of unknown quality without 9 adequate disinf...

Отзывы: