37 

1.

 

SAFETY PRECAUTIONS 

 
While our primary concern in designing the hydrogenerator was your safety, certain precautions 
must nevertheless be taken when operating any mechanical or electrical equipment.   
Please keep the following safety factors in mind when installing and operating the hydrogenerator, 
and  be  aware  at  all  times  of  the  electrical  and  mechanical  hazards  inherent  in  operating  the 
propeller. 
 

MECHANICAL HAZARDS 

The hydrogenerator's blades are made of a composite material and can rotate at a speed of over 
100 kph (62 mph).  
At this speed, the blades are practically invisible and can cause serious injuries.  

WARNING : WHEN INSTALLING THE HYDROGENERATOR, MAKE SURE THAT THE 
PROPELLER IS SAFELY POSITIONED OUT OF REACH. 

DO  NOT  ATTEMPT  TO  STOP  THE  PROPELLER  WITH  YOUR  HAND  WHILE  THE 
GENERATOR IS RUNNING. 
 
 

 

Electrical hazards 

Heat in wiring systems often results from undersized cables or faulty connections.  
Batteries have a very high current carrying capacity. A short

-

circuit in their cables may result in an 

outbreak of fire. To prevent this hazard, you must install a 50 amp fuse between the converter and 
each battery. 
If the fuse is defective, you must determine the reason before resetting or replacing it. 
 

WARNING : YOU MUST INSTALL AN EXTERNAL 50 AMP FUSE. 

 

WARNING  :  ALWAYS  PLACE  THE  HYDROGENERATOR  IN  THE  LIFTED  POSITION 
BEFORE STARTING WORK ON IT. 

 

 

Содержание CRUISING 300

Страница 1: ...s experienced by monohulls this hydrogenerator will radically change your energy management at sea and become your main source of power while sailing This product has been thoroughly inspected The pro...

Страница 2: ...ER 47 MOUNTING THE ELECTRONIC CONVERTER 47 5 ELECTRICAL INSTALLATION 48 THREE PHASE WIRING OF THE HYDROGENERATOR 48 USING A SOLAR PANEL 49 CONNECTING THE CONVERTER TO THE BATTERIES 50 INTERPRETATION O...

Страница 3: ...invisible and can cause serious injuries WARNING WHEN INSTALLING THE HYDROGENERATOR MAKE SURE THAT THE PROPELLER IS SAFELY POSITIONED OUT OF REACH DO NOT ATTEMPT TO STOP THE PROPELLER WITH YOUR HAND W...

Страница 4: ...t Operation Check the support structure blades and electric circuits on a regular basis Although the propeller blades are made of very strong materials they may warp or break if they come into contact...

Страница 5: ...3 or H 600 03 1 LIFTING BRACKET K 03 1 THREE BLADE P 240 03 1 PROPELLER EXTRACTION KIT EP 03 1 CONVERTOR CV 03 with its bag of connectors 1 hydrogenerator connector 1 solar connector 3 battery connect...

Страница 6: ...ables WATT SEA offers an optional connection kit with cable and waterproof power socket Ref PL 04 Bolts for fixing the bracket s stainless steel fork mountings to the hull Lifting lowering line 6 1 or...

Страница 7: ...rt the HSHC M5x20 screw 4 Hold the propeller with one hand and tighten the screw using the 4 mm 5 32 Allen key until the screw starts turning the propeller Exploded view of the shaft propeller washer...

Страница 8: ...and during lifting will be We recommend a length of 970 mm 38 in as a satisfactory compromise for most monohull installations The 610 mm leg is suitable for very large monohulls with a device install...

Страница 9: ...on a Pogo40 CN STRUCTURES The hydrogenerators are placed parallel to the rudders but approximately 30 cm 12 in to the inside to avoid their wakes Installation on a catamaran OUTREMER YACHTING Here th...

Страница 10: ...ur mounting system should be adapted accordingly The bracket must be adapted to the 8 mm diameter fork mountings that are securely mounted onto the transom These fork mountings must be mounted in such...

Страница 11: ...ring lifting is around 40 kg It is therefore recommended to rig a 4 1 to 6 1 hoist with a 6 mm diameter sheathed line hoist available in option at Watt Sea refs PA 04 and PA 04 HS depending on boat sa...

Страница 12: ...ing lines to avoid the cleat from opening unexpectedly N B When the hydrogenerator is submerged the leg should sit flush in the groove of the gudgeon provided for this purpose If this is not the case...

Страница 13: ...nverter must nevertheless be installed inside the boat preferably in the mechanical room in close proximity to the batteries WARNING WHEN RUNNING THE CONVERTER CAN REACH VERY HIGH TEMPERATURES AS SUCH...

Страница 14: ...ng the connection kit with a cable and waterproof power socket Ref PL 04 From here use a three phase cable to connect the hydrogenerator to the converter If the length of this cable is less than 10 me...

Страница 15: ...h the solar panels is 7 5VCC Wire the solar panel using the 2nd premounted plug CA 03 taking care of the polarity NEGATIVE SOLAR BLACK POSITIVE SOLAR RED WARNING RESPECT THE POLARITY OF THE SOLAR PANE...

Страница 16: ...possible to charge two battery units separately The 2 battery banks must be at the same voltage WARNING RISK OF OVERLOADING AND FIRE THE TWO BATTERY BANKS MUST BE THE SAME TYPE AND HAVE THE SAME VOLTA...

Страница 17: ...spannung max 1500 V Nennstrom 40 A 6 mm 50 65 A 16 mm Kabeldurchmesser 5 5 10 m NOTE Protect the plug in connectors from humidity and dirt Do not immerse the plug in connector in water Never lay out t...

Страница 18: ...conds The battery is full absorption voltage 14 3V 28 6V Please lift up the hydrogenerator Floating voltage maintained 1 long green flash every 5 seconds The battery is kept at 100 floating voltage 13...

Страница 19: ...fill in the profile page with the requested informations Activate Bluetooth on your phone or tablet Connect to the converter via the application the converter has a serial number of type CV 03 XXXX W...

Страница 20: ...ssible to the batteries See 4 6 Make sure that the propeller is not submerged and that it is not possible for the alternator to run during installation 5 Run the converter s power cables through to th...

Страница 21: ...600 W Nominal voltage Three phase 40 V Rated current 9 A Weight 8 2 kg 7 4 kg w Converter CV 03 Nominal power 600 W Absorption voltage 14 3 V 28 6 V Floating voltage 13 8 V 27 6 V Rated current 44 A...

Страница 22: ...minal voltage Three phase 40 V Rated current 9 A Weight 7 1 kg 6 3 kg w Converter CV 03 Nominal power 600 W Absorption voltage 14 3 V 28 6 V Floating voltage 13 8 V 27 6 V Rated current 44 A 22 A Sola...

Страница 23: ...bly turned off 2 The three phase cable has become completely disconnected In this case the LEDs flash from red to orange and then to green indicating that the battery is connected but that there is no...

Страница 24: ...on position and the quality of water flow The charts given below for the 600 and 300 models correspond with the measurements carried out on a motorboat with 200 mm 240 mm and 280 mm propellers and a c...

Страница 25: ...59 Power output in relation to boat speed The average production values are given for information purposes only and may vary depending on the sea conditions and the quality of the installation...

Страница 26: ...insed with fresh water Dismont regularly the propeller to clean the shaft from potential dirts The generator and propeller mountings should be regularly inspected to ensure that they are tight Inspect...

Страница 27: ...t P 200 03 Cruising three blade propeller 200 mm 7 9 in P 240 03 Cruising three blade propeller 240 mm 9 5 in P 280 03 Cruising three blade propeller 280 mm 11 in EP 03 Cruising propeller extraction k...

Страница 28: ...arged the propeller freewheels And the noise produced by the hydrogenerator changes thudding sound Hydrogenerator must then be lifted out of the water or if installed use the relay to short circuit th...

Страница 29: ...onsume energy The converter has a residual consumption as one LED is always lit It cuts out in the event of low voltage 11 9V in order to save the battery Ion lithium batteries The converter is design...

Страница 30: ...written consent of WATT SEA and must be returned by prepaid shipment Should the replacement of the WATT SEA product prove to be due to a defect covered by the warranty these shipment costs shall be r...

Страница 31: ...try Date of purchase of the hydrogenerator Serial no see installation manual of the hydrogenerator of the converter Type of boat Type of assembly on the transom if custom made please specify Condition...

Страница 32: ...e of purchase of the hydrogenerator Has the defect been confirmed Has the installation been carried out in compliance with the instruction manual Installer contact details Defective subassemblies to b...

Отзывы: