52
Interpretation of the converter's LEDs
-
When the converter
is not charging
, the battery
voltage is indicated by a
pulse
of color which changes
from green (12.8 V) to red (11.5 V).
-
When the converter
is charging
, the output power is
indicated by a
constant color
which changes from
violet to blue (120W), to light blue (240W) and finally
to white (480W).
-
Green or red colored
flashes
may
overlay
the
display of the constant color to indicate statuses or
anomalies :
SITUATION
VISUAL
COMMENTS
Absorption
voltage
reached
1 brief green
flash every 5
seconds
The battery is full
(absorption voltage
=14.3V/28.6V)
Please lift up the
hydrogenerator
Floating
voltage
maintained
1 long green
flash every 5
seconds
The battery is kept at
100%
(floating voltage =
13.8V/27.6V)
Overheating
1 red flash
every 5
seconds
The maximum box
temperature has been
reached
Generator
anomaly
2 red flashes
every 5
seconds
The hydrogenerator's
connection is defective
Overvoltage
at input
3 red flashes
every 5
seconds
The solar panel or the
hydrogenerator are
applying a voltage that
is too high
Another
anomaly
4 red flashes
every 5
seconds
Contact your distributor
OFF
CHARGE
U BATT (V) Power(W)
12,8/25,6
11,8/23,6
11,5/23,0
480+
240
120
60
>0
INFOS LED
100% ABS
100% FLOAT
HIGHT TEMP.
CONNECTION PB
INPUT VOLT.
OTHER