Table 10 - Cyclic parameters
Index
Name
Access
Type
Description
48
OverCurrentError
Read
Bool
If set the pump has an over current
error. Please follow onscreen
instructions
49
OverVoltageError
Read
Bool
If set the set the pump has an over
voltage error. Please follow onscreen
instructions
50
Guard/Interlock
Read
Bool
If set then the guard has been opened.
Please follow onscreen instructions to
clear.
51
FlowHi-LoActive
Read
Bool
If set then the flow sensor low warning is
active
52
FlowLo-LoActive
Read
Bool
If set the flow sensor low alarm is active
53
PressureHi-LoActive
Read
Bool
If set the pressure low warning is active
54
PressureLo-LoActive
Read
Bool
If set the pressure low alarm is active
55
FlowHi-HiActive
Read
Bool
If set the flow high alarm is active
56
FlowLo-HiActive
Read
Bool
If set the flow high warning is active
57
PressureHi-HiActive
Read
Bool
If set the pressure high alarm is active
58
PressureLo-HiActive
Read
Bool
If set the pressure high warning is active
59
FlowSensorError
Read
Bool
If set there is an error condition on
sensor input 1
60
PressureSensorError
Read
Bool
If set there is an error condition on
sensor input 2
61
AnybusNetworkMode
Read
Bool
If set the pump is in Ethernet IP Mode
62
AnybusNetworkActive
Read
Bool
If set Ethernet IP is active on the device
64
ErrorAcknowledge
Write
Bool
Used to acknowledge errors over
EtherNet IP
106
PressureSwitchError
Read
Bool
Reports the current active batch by ID
82