4.
There are 20 character slots. Press
NEXT
to confirm your character and to move onto the
next. Press
PREVIOUS
to return to the last character slot.
5.
Once you have filled the character slots press
FINISH
. This will return you to the
GENERAL
SETTINGS
screen.
6.
Power the pump off and on again to apply the asset number.
Failsafe speed
A failsafe speed is a dedicated speed the pump uses if an error occurs. Use this to prevent the pump
stopping in the event of an error.
Example:
disconnect the RJ45 cable from the pump while running on EtherNet/IP™ mode and the
pump will error.
l
If failsafe speed is enabled, the pump will run at the failsafe speed and the network error
message will display.
l
If failsafe speed is not enabled, the pump will stop running and the network error message
will display.
Once the error is acknowledged, the pump will run as normal.
58
m-730en-en-09 02-02-22