This product does not comply with the ATEX directive and must not be used in
explosive atmospheres.
Ensure the chemicals to be pumped are compatible with the pumphead,
lubricant (where applicable), tubing, pipework and fittings to be used with the
pump. Please refer to the chemical compatibility guide which can be found at:
. If you need to use the pump with any other
chemical please contact Watson-Marlow to confirm compatibility.
If the Auto Restart feature is enabled it may cause the pump to start as soon
as power is turned on.
Auto Restart only affects operation of manual mode and EtherNet/IP™ mode.
If Auto Restart is enabled the "!" Symbol is shown on the screen to warn users
that the pump may operate without any manual intervention (pump resumes
with previous settings).
Do not use Auto Restart for more than:
•
1 mains power start per 2 hours
We recommend remote control where a high number of starts is required.
If the pump is configured to EtherNet/IP™ mode it will respond to remote
commands at any time including immediately after power on. The pump may
operate without any manual intervention (e.g. a remote setpoint could start
the pump with no key press required).
There are moving parts inside the pumphead. Before opening the tool-
unlockable guard or tool-unlockable track, ensure that the following safety
directions are followed:
1.
Ensure the pump is isolated from the mains power.
2.
Ensure that there is no pressure in the pipeline.
3.
If a tube failure has occurred, ensure that any fluid in the pumphead
has been allowed to drain to a suitable vessel, container or drain.
4.
Ensure that appropriate Personal Protective Equipment (PPE) is worn.
Primary operator protection from rotating parts of the pump is provided by the
pumphead safeguard. Note that safeguards differ, depending on the type of
pumphead. See the pumphead section of the manual.
m-730en-en-09 02-02-22