If the Auto Restart feature is enabled it may cause the pump to start as soon
as power is turned on.
Auto Restart only affects operation of manual mode and EtherNet/IP™ mode.
If Auto Restart is enabled the "!" Symbol is shown on the screen to warn users
that the pump may operate without any manual intervention (pump resumes
with previous settings).
Do not use Auto Restart for more than:
•
1 mains power start per 2 hours
We recommend remote control where a high number of starts is required.
If the pump is configured to EtherNet/IP™ mode it will respond to remote
commands at any time including immediately after power on. The pump may
operate without any manual intervention (e.g. a remote setpoint could start
the pump with no key press required).
Flow units
The current chosen flow unit is displayed on the right hand side of the screen. To change flow units
move the selection bar over the flow unit menu entry and press
SELECT
.
1.
Use the
∧
/
∨
keys to move the selection bar over the required flow unit, then press
SELECT
.
All flow rates displayed on screens will now be in the chosen units.