Table 10 - Cyclic parameters
Index
Name
Access
Type
Description
12
ResetRevolutionCount
Write
Bool
Set to 1 to reset the revolution count. Set
to 0 to allow the revolution count to
increment.
13
FlowCal
Read
Uint32 Reports the Flow calibration value in μL.
14
RunHours
Read
Uint32
Reports the number of hours the pump
has run
15
SensorFlowRate
Read
SInt32
Reports a value if the flow sensor is
setup
16
SensorPressure
Read
SInt32
Reports a value if the pressure sensor is
setup
17
PressureLo-
HiWarningSp
Read
SInt32
Displays the Pressure low warning band
set point in deci-psi
18
PressureHi-
LoWarningSp
Read
SInt32
Displays the Pressure high warning band
set point in deci-psi
19
PressureLo-LoAlarmSp
Read
SInt32
Displays the Pressure low alarm band set
point in deci-psi
20
PressureHi-HiAlarmSp
Read
SInt32
Displays the Pressure high alarm band
set point in deci-psi
21
FlowSensorLo-
HiWarningSp
Read
SInt32
Displays the Flow low waning band set
point in μL
22
FlowSensorHi-
LoWarningSp
Read
SInt32
Displays the Flow high warning band set
point in μL
23
FlowSensorLo-
LoAlarmSp
Read
SInt32
Displays the Flow low alarm band set
point in μL
24
FlowSensorHi-
HiAlarmSp
Read
SInt32
Displays the Flow high alarm band set
point in μL
25
FlowTotaliser
Read
UInt32
Displays the totalised flow value in deci-
ml
m-730en-en-09 02-02-22