Regeneration
Regeneration
2CI Valve
(Regeneration Time: 90 mins) - Default
This valve is designed to regenerate when the capacity is reached or the day override has
been actuated due to insufficient water volume. The calculated capacity is subject to the
size of the unit and inlet water hardness.
Replenishment of Salt Supply
During each regeneration a small amount of salt is consumed, thus requiring periodic
replenishment for a continuous supply of treated water (the frequency and salt dosage level is
dependent on the regeneration schedule).
We recommend to maintain the salt level in the brine tank to 1/2 to 2/3 full. The water level in
the brine tank is maintained automatically and does not require manual intervention.
Note:
The water level is usually below the salt level & therefore cannot be seen (this is as it
should be). Always replenish salt before the supply is exhausted. No extra water is required
when topping up the salt level.
Type of Salt to Use
Any type of water softener salt may be used, but for best results, we recommend using coarse
solar salt called "water softener salt" or alternatively "pool salt".
Brine Tank Clean-Out
To help prevent service problems the brine tank should be emptied and flushed out with a
garden hose, when dirt and other insolubles accumulate.
Clean out with a wet/dry vacuum. Then add approximately 15L of water and refill with salt.
Media Replacement
Resin ordering code:
RMK-SOL110
for SOL110-2CI,
RMK-SOL160
for SOL160-2CI,
RMK-SOL270
for SOL270-2CI &
RMK-SOL380
for SOL380-2CI .
Customer Service Helpline at
1300 140 140
(AU) and
0800 130 140
(NZ) for more details.
Media Replacement Instructions:
1. Unscrew and remove the valve from the pressure tank.
2. Use a wet/dry vac to remove old media.
3. Follow Media Installation on page 15.