WL200 Manual
Page 42 - Revision: 4-29-2019
1.
Dispensing Won’t Stop when Not Holding the Dispensing Button
Possible Reason
Solution
Too much water pressure.
Recommend 40-60 psi for the
WL200 Water Treatment
System to operate properly.
The correct input water pressure is critical to the performance of
the unit to allow solenoids to open.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 40-60 psi.
Bad Display PCB
Replace Front PCB
P/N 12-8615 – Factory P/N EN-6086
Debris in the Solenoid
Inspect Solenoid for debris and clean out as needed.
Dispensing Button Stuck
Dirt or Foreign material is filling the gap around the push-buttons.
Inspect the push buttons and clean surrounding area. Inspect
faucet assembly inside the unit and clean as necessary.