WL200 Manual
Page 35 - Revision: 4-29-2019
WL200 COUNTER TOP DRAINING INSTRUCTIONS
Drain the WL200 Water Treatment System for transportation.
WARNING!
STORE UNIT EMPTY. ALWAYS SANITIZE BEFORE REUSE.
The unit must be completely drained and sealed before storing to avoid stagnation and reduce
microbial growth).
Turn off Water Supply and Bleed Water Pressure
1.
Isolate the WL200 Water Treatment System from feed
water by turning off the supply.
2.
Dispense cold still water to relieve any pressure built up in
the system.
3.
Remove the water supply line from the inlet line bulkhead
fitting at back of the WL200 Water Treatment System.
4.
Depress Cold Water Dispense Button until all Cold Water has drained from the WL200 Water
Treatment System.
5.
Depress Hot Water Dispense Button until all Hot Water has drained from the WL200 Water
Treatment Machine.
Water Supply Line
Содержание WL200
Страница 16: ...WL200 Manual Page 16 Revision 4 29 2019 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...
Страница 22: ...WL200 Manual Page 22 Revision 4 29 2019 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...
Страница 28: ...WL200 Manual Page 28 Revision 4 29 2019 WL200 COUNTER TOP WATER FLOW DIAGRAM...
Страница 29: ...WL200 Manual Page 29 Revision 4 29 2019 WL200 TOWER WATER FLOW DIAGRAM Water In Solenoid Valve Condenser Faucet...