WL200 Manual
Page 36 - Revision: 4-29-2019
WL200 TOWER DRAINING INSTRUCTIONS
Draining Notes
Drain the WL200 Water Treatment System for transportation.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be
completely drained
before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Always sanitize before use to
eliminate any potential microbiological contaminates.
Disable Cold Tanks
1.
Turn off the Red Power Switch to disable the compressor. O = OFF
Turn off Water Supply and Bleed Water Pressure
2.
Isolate the unit from feed water by turning off the supply.
3.
Dispense cold still water to relieve any pressure built up in the system.
4.
Remove the water supply line from the inlet line bulkhead fitting at back of machine.
5.
Install dust cap or plug into water supply line bulkhead fitting.
Drain the Cold Water Tank and Circuit
6.
Remove lower front panel to access tank feed lines.
7.
Disconnect tank line feed line from cold inlet solenoid to
drain into basin or catch.
8.
Reconnect tubing into inlet elbow once drained.
9.
Dry inside of unit if necessary.
10.
Replace lower front panel.
Содержание WL200
Страница 16: ...WL200 Manual Page 16 Revision 4 29 2019 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...
Страница 22: ...WL200 Manual Page 22 Revision 4 29 2019 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...
Страница 28: ...WL200 Manual Page 28 Revision 4 29 2019 WL200 COUNTER TOP WATER FLOW DIAGRAM...
Страница 29: ...WL200 Manual Page 29 Revision 4 29 2019 WL200 TOWER WATER FLOW DIAGRAM Water In Solenoid Valve Condenser Faucet...