3.
Steady Drip Out of Faucet
Possible Reason
Solution
Debris in Solenoid
Inspect Solenoid for debris and clean out as needed.
4.
Irregular / Intermittent Dispensing
Possible Reason
Solution
Too much water pressure.
Recommend 40 to 60 psi for
WL200 Water Treatment
System to operate properly.
Check water pressure at the inlet bulkhead with a water pressure
gauge.
Additional method of verification is to turn off water to unit and
press the dispense button. Does the solenoid open without water
pressure to the unit? Listen for solenoid to activate, not button
“click”.
Adjust water pressure to 40-60 psi.
Loose or bad connection on
the Front Dispensing PCB or
Solenoid Connector
Check that they are connected properly and tightened.
Solenoid
If both the Water Pressure and PCB have been ruled out, then it is
the Solenoid.
Replace Solenoid.
Dispensing button is broken on
PCB
Check PCB for loose or damaged button. Replace PCB as
necessary.
5.
Small Amount of Water Periodically Dispenses from Faucet Automatically
Possible Reason
Solution
Cold or Hot Water Solenoid
Valve malfunction`
Inspect valve components for proper function. Replace as
necessary.
Obstruction in Solenoid
housing is preventing proper
sealing of component
Pre-determine whether water being dispensed is Hot / Cold.
Isolate the water supply; push the DISPENSE button to release the
line pressure, and remove the coil affixed to the Solenoid stem.
Remove the stem from the solenoid housing and allow water from
the tank to flush out the contaminate(s).
Содержание WL200
Страница 16: ...WL200 Manual Page 16 Revision 4 29 2019 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...
Страница 22: ...WL200 Manual Page 22 Revision 4 29 2019 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...
Страница 28: ...WL200 Manual Page 28 Revision 4 29 2019 WL200 COUNTER TOP WATER FLOW DIAGRAM...
Страница 29: ...WL200 Manual Page 29 Revision 4 29 2019 WL200 TOWER WATER FLOW DIAGRAM Water In Solenoid Valve Condenser Faucet...