WL200 Manual
Page 5 - Revision: 4-29-2019
WARNING!
CONNECT TO POTABLE WATER SUPPLY. This system is to be used for water only and is
not intended for use where water is microbiologically unsafe or with water of unknown quality
without adequate disinfection before or after the system.
WARNING!
TIP HAZARD. Dispenser could tip or fall causing serious injury. Always install unit on a
firm, flat, and level surface and secure the
WL200 Water Purification System to the base cabinet
with the screw provided to lock the components together. Secure unit to cabinet, wall, or floor if
needed. Never place heavy items on top of unit and never climb, stand, or hang on unit or storage
cabinet to prevent injury and damage.
WARNING!
UNIT IS HEAVY. TWO PERSON LIFT REQUIRED. Transport unit empty and always use
material handling equipment or two people with proper lifting technique to reduce injury risk.
WARNING!
STORE AND TRANSPORT UNIT EMPTY.
ALWAYS SANITIZE BEFORE USE.
The unit must be
completely drained
before storing to avoid stagnation and reduce
microbiological contamination (potential bacterial growth). Always sanitize before use to
eliminate any potential microbiological contaminates.
CAUTION!
INDOOR USE ONLY. Intended for Household Use. Never expose to direct sunlight,
heat sources, or ambient air temperature above 37°C (100°F) or below 2°C (35°F). Install indoors
and keep unit away from excessive humidity. Never expose to freezing temperatures. Ensure
there is adequate clearance around the unit to allow refrigeration system condenser to dissipate
heat. Warmer environments require more clearance around the unit. Minimum clearance around
all surfaces of the machine is 2-inches. Installs where the ambient temperature exceeds 27°C
(80°F), require a minimum of 4-inches clearance for proper heat dissipation and efficient
operation.
CAUTION!
USE A WATER PRESSURE REGULATOR. Waterlogic will not be responsible for injury or
damage caused by excessive water pressure. Input or feed pressure must be 40 psi to 60 psi. Be
aware of any potential pressure surges caused by building/municipal pumping stations.
CAUTION!
USE UV STABILIZED SUPPLY LINES. Feed the unit with a potable ambient or cold
water supply only. Feed water over 37°C (100°F) can damage the treatment components. Water
block devices and external leak detectors are strongly recommended. Locate the unit as close to
the water supply and the electrical connections as possible. Locate the unit as close to the water
supply and the electrical connections as possible. Immediately isolate or close water supply valve
and contact service representative if leak is noticed.
Contact Waterlogic for assistance or help finding an Authorized Service Representative.
Содержание WL200
Страница 16: ...WL200 Manual Page 16 Revision 4 29 2019 WL200 COUNTER TOP DRAWINGS with PART NUMBERS Wetted Parts...
Страница 22: ...WL200 Manual Page 22 Revision 4 29 2019 WL200 TOWER DRAWINGS with PART NUMBERS Wetted Parts...
Страница 28: ...WL200 Manual Page 28 Revision 4 29 2019 WL200 COUNTER TOP WATER FLOW DIAGRAM...
Страница 29: ...WL200 Manual Page 29 Revision 4 29 2019 WL200 TOWER WATER FLOW DIAGRAM Water In Solenoid Valve Condenser Faucet...