IMPORTANT

READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING THE INSTALLATION. PROPER INSTALLATION
WILL PROVIDE SAFE AND EFFICIENT SERVICE AND AVOID NEEDLESS EXPENSE NOT COVERED BY THE
WARRANTY. READ THE PRODUCT WARRANTY CONTAINED IN THIS MANUAL AND REMEMBER TO FILL
OUT AND RETURN TO THE MANUFACTURER ALL RELEVANT WARRANTY CARDS AND CERTIFICATES.
SHOULD YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR LOCAL DEALER OR REFER TO THE

GETTING SERVICE FOR YOUR WATER HEATER

SECTION OF THIS MANUAL.

SAVE THIS MANUAL FOR FUTURE REFERENCES.

RESIDENTIAL OIL-FIRED WATER HEATER 

OWNER’S MANUAL

INSTALLATION AND OPERATING INSTRUCTIONS

If the information in these instructions is
not entirely followed, a fire or explosion
may result causing property damage, per-
sonal injury or death.

DO NOT STORE,

use gasoline or any other

flammable vapours or liquids in the 
vicinity of this or any other appliance.

DO NOT USE

gasoline, crank case oil or

oil containing gasoline.

DO NOT TAMPER

with the unit or 

controls.

DO NOT LEAVE

paper or rags close to the

burner or the water heater.

WHAT TO DO IF YOU DETECT OIL

Immediately call your oil supplier.

Installation and service must be performed by a
qualified installer, service agency or the oil supplier.

WARNING

WARNING

For your records, write the model and serial number here:

Model # ____________________________

Serial #

____________________________

This water heater 

IS NOT

design certified for

installation outdoors.

GI-IM001En-0211

54000006

© 2011  Giant Factories Inc.  Printed in Canada

C          US

ISO 9001

REGISTRED

Содержание RESIDENTIAL OIL-FIRED WATER HEATER

Страница 1: ... not entirely followed a fire or explosion may result causing property damage per sonal injury or death DO NOT STORE use gasoline or any other flammable vapours or liquids in the vicinity of this or any other appliance DO NOT USE gasoline crank case oil or oil containing gasoline DO NOT TAMPER with the unit or controls DO NOT LEAVE paper or rags close to the burner or the water heater WHAT TO DO I...

Страница 2: ...ntilation Air Supply 3 Requirements for Unconfined Spaces 4 Requirements for Confined Spaces Indoor Combustion and Ventilation Air 4 Requirements for Confined Spaces Outdoor Combustion and Indoor Ventilation Air 4 Requirements for Confined Spaces Outdoor Combustion and Ventilation Air 4 Air duct sizing 5 Louvers and Grilles 6 Corrosive Atmospheres 6 Venting 6 Chimney requirements 6 Flue piping 6 D...

Страница 3: ...heater to operate properly it must be supplied with an uninterrupted flow of clean combustion and ventilation air The area around the water heater must always be kept clean and clear of debris An inadequate supply of air to the water heater will produce a bright yellow burner flame causing soot ing in the combustion chamber on the burner and in the flue tube This can result in damage to the water ...

Страница 4: ...ly communi cating with interior areas that have in turn adequate infiltration from the outdoors Requirements for Confined Spaces Outdoor Combustion and Indoor Ventilation Air A water heater that is located in a confined space and that obtains its combustion air from outdoors and ventilation air from within the conditioned space of the building should be provided with two permanent openings one nea...

Страница 5: ...losure b horizontal duct s as shown in Figure 7 with an equivalent length of less than 50 ft 15 m having a free flow area of not less than one 1 square inch per 2 000 BTU h 11 cm2 kWh of the total input of all oil fired appliances in the enclosure and c air openings that communicate directly with the outdoors as shown in Figure 6 having a free flow area of not less than one 1 square inch per 4 000...

Страница 6: ...nnected to a ver tical chimney The chimney must be properly con structed and sized clean and free of soot creosote and obstructions able to generate sufficient draft to evacuate the products of combustion outdoors and be lined with a tile or metal liner Inspect the chimney and make any repairs necessary before installing the water heater To prevent downdrafts the chimney flue should extend at leas...

Страница 7: ...tional Electrical Code NFPA 70 in the United States Before installing the switch remember to DIS CONNECT THE POWER SUPPLY to the water heater Failure to follow these instructions can result in property damage personal injury or death Installation 1 Install the pre assembled flue collar blocked vent switch assembly over the flue outlet on the water heater see Figure 9 2 Wire the switch to the aquas...

Страница 8: ...is imperative that open flame is not applied to the inlet and outlet fittings as heat will damage or destroy the plastic lined fittings This will result in premature failure of the fittings which is not covered by the warranty 8 INSTALLATION INSTRUCTIONS FLUE COLLAR BLOCKED VENT SWITCH VENT PIPE FLUE OUTLET MANUAL RESET BUTTON FLUE COLLAR BLOCKED VENT SWITCH ASSEMBLY Figure 9 Figure 10 1 Flue coll...

Страница 9: ...ystem When the water heater operates the heated water expands creating a pressure build up This is a natural function and is one of the reasons for installing a temperature and pressure relief valve If the cold water supply line has a built in water meter check valve or pressure reducing valve a suitable expansion tank must be installed to prevent pressure build up or water hammer effect Otherwise...

Страница 10: ... proper burner settings Wiring This water heater uses an external electrical source for power It must be electrically grounded in accordance with all local codes or in the absence of such codes the latest edition of the CSA C22 1 Canadian Electrical Code in Canada and or the latest edition of the National Electrical Code NFPA 70 in the United States Failure to properly ground this water heater can...

Страница 11: ... piping would have been in the past treated with chemicals for cleaning or sealing the system 3 If this water heater is to be used for space heating make sure that all safety codes are respected Pay special attention to safety valve pressure and expansion tanks Figure 11 L1 N Aquastat Fuse L1 N Gnd Oil Burner Junction Box Electrical Wiring Diagram For White Rodgers Aquastat Model 11B76 Black White...

Страница 12: ...rom the water heater relief valve and premature failure of the heater due to expansion of the water during the heating cycle 7 Before acquisition of a water heater for space heating application it is necessary to have the area of intended use sized by a qualified technician This will ensure that an adequate water heating capacity will be available for both heating and potable water supply and that...

Страница 13: ...e blocking effect of louvers and grilles L Venting Is the flue baffle installed in the flue tube L Has the water heater been vented separately from all other oil fired appliances L Have all horizontal runs of vent pipe been installed with a minimum rise of 1 4 inch per foot 21 mm m of run L Water Piping Is the dip tube installed in the cold water inlet L Has a temperature and pressure relief valve...

Страница 14: ...ditions before fine tuning combustion The warm up time is ideal for testing the oil pump pressure Water Temperature Regulation The higher the setting the greater the risk of scald ing Hot water can cause third degree burns in under one 1 second at 160 F 71 C in five 5 seconds at 140 F 60 C and in thirty 30 seconds at 130 F 54 C In households where there are children physically challenged individua...

Страница 15: ... Excess combustion air causes a bright roar ing fire and high stack temperatures resulting in poor fuel efficiency After the burner has been firing for 10 15 minutes take a smoke sample with a Bacharach smoke sampler or other approved device Then take a sam ple of the flue gases and test for CO using a combus tion analyser The smoke spot should not exceed Trace on the Bacharach Scale The water hea...

Страница 16: ...he life expectancy of the water heater is reduced where a water softener is introduced to fight hard water because the sodium salts added by a softener make this water extremely conductive In these conditions the anodes are consumed more rapidly and should be verified every year In certain water conditions the anodes will react with the water producing discoloured or smelly water The most common c...

Страница 17: ...y phone at 1 800 363 9354 To help serve you in a quick and efficient way always have the following information ready a Model number b Serial number c Date of installation d Where the water heater was purchased e Complete address where the water heater is installed f A description of the problem 1 2 3 4 5 7 8 6 9 10 I D Description 1 Aquastat 2 Oil burner 3 Brass drain valve 4 Overflow tube 5 Dip t...

Страница 18: ...mage caused by not having the water heater installed adjacent to a free flowing drain in the event of water leakage 10 If the heater is operated at water temperatures exceeding the maximum setting of the operating or high limit control or the heater is not supplied with potable water free to circulate at all times 11 If the heater has experienced the effect of thermal expansion due to excessive pr...

Отзывы: