Содержание 16NG50/16LP50

Страница 1: ...GAS CONTINUOUS FLOW WATER HEATERS OPERATING INSTRUCTIONS GAS CONTINUOUS FLOW FOR MODELS 16NG50 16LP50 16NG60 16LP60 20NG50 20LP50 20NG60 20LP60 26NG50 26LP50 26NG60 26LP60 ...

Страница 2: ...2 OPERATING INSTRUCTIONS ...

Страница 3: ...r operation 4 If any gas smell comes from the unit do not use naked flames to test for gas leaks Turn off the gas supply and power and contact your plumber or reece customer care on 1800 080 055 5 If a power failure occurs the remote controls will not function and the thermann unit will not supply hot water until power is restored IMPORTANT SAFETY INSTRUCTIONS 1 CLOSE 1 CLOSE No Fire Prohibited 1 ...

Страница 4: ...sturbance Install away from the appliance MEASURES TO BE TAKEN DURING ELECTRICAL STORMS Power surges caused by lightning can damage the electronic parts Therefore turn off the main power during electrical storms IMPORTANT SAFETY INSTRUCTIONS SECURE SERVICE SPACE Make sure there is enough space around the unit for checking service and maintenance 5 Check ...

Страница 5: ...a licensed plumber for installation relocation or connection to solar units IMPORTANT SAFETY INSTRUCTIONS Caution Pull No wet hand Close Close Caution Close Close FREEZE PREVENTION This unit comes equipped with internal electric heaters that prevent the water inside the unit from freezing To enable this freeze prevention system to operate there must be an electrical power supply connected to the u...

Страница 6: ...ave been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance DANGER OF WET HANDS Do not touch power plug with wet hands It can cause electric shock INSERT POWER PLUG FULLY INTO POWERPOINT Check that the power plug is clean and undamaged then fully insert into the p...

Страница 7: ...cted water temperature Error messages flash in the event of a failure ON Indicator Indicates power is on to the system ON OFF Button Power switch to operate this control PRIORITY Indicator Indicates this controller has priority control over the other controller CMR 2254 Main remote Controller This remote controller is intended to be used in the kitchen laundry room or utility area Flame Logo Indic...

Страница 8: ...trol Digital Monitor Indicates the selected water temperature Error messages flash in the event of failure Flame Logo Indicator Indicates that a hot water faucet is open and that control of the temperature is by another controller UP DOWN Button Increase or decrease the desired water temperature PRIORITY Button PRIORITY Button to set the water temperature on this remote controller PRIORITY Indicat...

Страница 9: ...ontroller 5 Turn on the hot water tap or shower Flame logo indicator will illuminate after a short delay This indicator will remain illuminated until the hot water tap or shower is turned off 6 The hot water temperature can be altered at any time during the operation by pushing UP DOWN button or located on the controller Main Remote Controller Bathroom Ensuite Remote Controller Energy saving Mode ...

Страница 10: ...vent small children from scalding 2 For kitchen and laundry use set the MAIN CONTROL to 60 C or the desired temperature 3 For showering use settings between 37 C 39 C and no cold water will be needed to be mixed and if other hot or cold water taps are used the temperature will be maintained 4 When bathroom remote controller is turned ON the temperature can be adjusted between 37 to 48 C 16 20 mode...

Страница 11: ...HECK GAS SUPPLY AND PRESSURE 141 RESIDUAL FLAME SAFETY DEVICE CALL REECE CUSTOMER CARE 1800 080 055 311 321 THERMISTOR WIRE BREAKAGE CALL REECE CUSTOMER CARE 1800 080 055 611 COMBUSTION FAN FAILURE CALL REECE CUSTOMER CARE 1800 080 055 740 750 760 COMMUNICATION FAILURE BETWEEN REMOTE CONTROLS PCB TURN OFF POWER AND TURN ON AGAIN MAINTENANCE These units can be cleaned using warm soapy water and a s...

Страница 12: ...esperson licensed to install this product Normal wear and tear Inadequate or complete lack of maintenance Chemical electrochemical or electrical influences Harsh detergents or abrasive cleaners used on product finishes EXCLUSIONS To the fullest extent permitted by law Reece excludes all liability for damage or injury to any person damage to any property and any indirect consequential or other loss...

Страница 13: ...Hot Water Units are covered by Reece for any cost of labour and parts in the event of a component failure due to any defects that may arise either from workmanship and or faulty material The Warranty commences on the date of Installation Domestic Heat Exchanger 10 years parts All components 3 years parts labour Commercial All components 1 year parts labour WARRANTY pH 6 5 to 8 5 Sodium Up to 150 m...

Страница 14: ...14 OPERATING INSTRUCTIONS ...

Страница 15: ...15 OPERATING INSTRUCTIONS ...

Страница 16: ...Works for you www reece com au thermann 20732910 ...