page 11
POWER LOSS
If the power goes out for less than two hours, the system will automatically reset
itself. If an extended power outage occurs, the time of day will flash on and off
which indicates the time of day should be reset.
The system will remember the rest.
ERROR MESSAGE
If the word “ERROR” and a number are alternately flashing on the display
record the number and contact the dealer or manufacturer for help.
This indicates that the control valve was not able to function properly.
POWER LOSS & ERROR DISPLAY
GENERAL OPERATION
When the system is operating one of three
displays will be shown. Pressing NEXT will alternate
between the displays. One of the displays is the
current time of day. Depending the system configura-
tion, the second display is one of the following: days
remaining or gallons remaining. Days remaining is the
number of days left before the system goes through a
regeneration cycle. Capacity remaining is the number
of gallons that will be treated before the system goes
through a regeneration cycle. The third display is an
option and, if used, will show the number of pounds of
salt remaining in the brine tank. The user can scroll
between the displays as desired using NEXT.
If the system has called for a regeneration that will
occur at the preset time of regeneration, the words
REGEN TODAY will appear on the display.
When water is being treated (i.e. water is flowing
through the system) the word “Softening” or “Filtering”
flashes on the display.
NORMAL OPERATING DISPLAYS
ß
ß
ß
or
ß
ß
or
ß
ß
ß
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”
REGENERATION MODE
Typically a system is set to regenerate at a time of low water usage. If there is a
demand for water when the system is regenerating, untreated water will be delivered.
When the system begins to regenerate, the display will change to include information
about the step of the regeneration process and the time remaining for that step to be
completed. The system runs through the steps automatically and will reset itself to provide treated water when the
regeneration has been completed.
MANUAL REGENERATION
Sometimes there is a need to regenerate before the control valve calls for it, usually referred to as manual
regeneration. This is needed when a period of heavy water usage is
anticipated or when the system has been operated without salt.
•
To initiate a manual regeneration at the preset delayed regeneration
time, press and release “REGEN”. The words “REGEN TODAY”
will flash on the display to indicate that the system will
regenerate at the preset delayed regeneration time.
• If you pressed the “REGEN” button in error, pressing the button again will cancel the
command. Note: If the regeneration time is factory set to “on 0” there is no set delayed regeneration time so
“REGEN TODAY” will not activate if “REGEN” button is pressed.
• To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system
will begin to regenerate immediately. The command cannot be cancelled.
REGEN TODAY will
Flash if a regeneration
is expected “Tonight.”