page 5
Gallons
Capacity
Regeneration
Time Option
Day Override
Result
AUTO
NORMAL
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the
Time.
AUTO
NORMAL
Any number
or 14 day
default
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity falls below
capacity...
or the specified number of days between regenerations is reached.
Any
number
NORMAL
oFF
Reserve capacity not automatically estimated. Regeneration occurs at the next Re
when gallons capacity reaches 0
oFF
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of da
regenerations is reached.
Any
number
NORMAL
Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity reaches 0
number of days between regenerations is reached.
AUTO
On O
oFF
Reserve capacity automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration is not allowed to be set because regeneration will always occ
gallons capacity reaches 0.
Any
number
On O
oFF
Reserve capacity not automatically estimated.
Regeneration occurs immediately when gallons capacity reaches 0.
Time of regeneration is not allowed to be set because regeneration will always occ
AUTO
NORMAL on 0
oFF
Reserve capacity automatically estimated.
Regeneration occurs when gallons capacity falls below the reserve capacity at the
Time or regeneration occurs immediately after 10 minutes of no water usage whe
reaches 0.
AUTO
NORMAL on 0 Any number
Reserve capacity automatically estimated.
Regeneration occurs at the next Regen Set Time when gallons capacity falls below
capacity or the specified number of days between regenerations is reached, or reg
immediately after 10 minutes of no water usage when gallon capacity reaches 0.
Any
number
NORMAL on 0 Any number
Reserve capacity not automatically estimated.
Regeneration occurs at the next Regen Set Time when the specified number of da
regenerations is reached, or regeneration occurs immediately after 10 minutes of
when gallon capacity reaches 0.
SOFTENER SETUP DETAIL TABLE
This table is to be used as a guide or shortcut to the settings made in Step 3I, 8S, and 9S. For quick programming
use the recommended settings shown in row 3 below in bold italic type.