3.16 RS485 Communication (RS485)
Set the RS485 communication. WAT-233 can be controlled through OSD operation by RS485 communication. Connect a communication cable between
the A5 and B5 terminals of the I/O connector and control the OSD menu by sending commands from PC or Pelco-D protocol compatible DVR / controller etc.
Move the cursor to RS485 with the UP / DOWN key and press the ENTER key, the RS485 menu will be displayed. Use the UP / DOWN key to move the cursor
up and down and use the the LEFT / RIGHT key to set the item you want to.
*For details about the voltage applied to the A5 to B5 terminals of the I/O connector and connection of the communication cable,
refer to the H / W manual.
STOP BIT
Set the stop bit. Stop bits can be set to 1 or 2.
*Default : 1
BAUDRATE
Set the baud rate. The baud rate can be set from 2400, 4800, 9600, 19200, 38400, 57600 and 115200.
*Default : 9600
Data bits are fixed to 8 bits.
DATA BIT
Since the item simply displays data bits, you can not change settings
PARITY
Set the parity bit. The parity bit can be set from OFF, ODD and EVEN.
*Default : OFF
PROTOCOL
Display supported protocols. The protocol used for RS485 communication is Pelco-D.
(RS485 Menu)
ENTER
Since the item simply displays supported protocols, you can not change settings.
ADDRESS
Set the camera address. The address can be set in the range of 000 - 255.
*Default : 000
OPERATION
55