3.8.3.4 Day/Night State Output Mode (D/N STATE OUT)
Set the day/night status output mode (D/N STATE OUT). In the day/night status output mode, it is possible to conduct between the A2 and B2 terminals
of the I/O connector in conjection with the change od day/night mode. By connecting an ifrared emitter etc. between the terminals, it is possible to turn
on the infrared emitter in the night mode with the day/night function, and turn off the infrared emitter in the day mode. Use the LEFT / RIGHT keys
to select OFF, ON, DAY / NIGHT.
*Default : OFF
*Refer to the H/W manual for details about voltage / output current between the A2 and B2 terminals of the I/O connector and connection of
the infrared emitter.
3.8.3.5 Day/Night function External Control Mode (D/N EXT CTL)
Sets the Day/Night function external control mode (D/N EXT CTL). Day/Night function external control mode can switch from Day mode to Night mode by
applying voltage between A1 - B1 terminals of the I/O connector, independent of ambient illuminance. Use the LEFT / ZRIGHT ket to select ON / OFF.
*Default : OFF
AUTO
OFF
Between A2 and B2 terminals is open.
DAY/NIGHT
ON
Between A2 and B2 pins is always on.
Between 2 and B2 pins, it conducts in night mode and opens in day mode.
LEFT/RIGHT
LEFT/RIGHT
*Refer to the H/W manual for details about the voltage, current and connection etc. applied between
ON
DAY/NIGHT
ON
OFF
DAY/NIGHT
D/N STARE OUT
OPERATION
OFF
ON
DAY/NIGHT
D/N EXT CTL
OPERATION
AUTO
OFF
It does not switch between day mode and night mode by external control.
Applying voltage between A1 and B1 terminals switches from day mode to night mode.
terminals A1 and B1.
40