![Wassp DRX Скачать руководство пользователя страница 41](http://html2.mh-extra.com/html/wassp/drx/drx_installation-manual_3493749041.webp)
Page 80 of 102
Page 81 of 102
Doc: DRX Installation
Version: 7.1 January 2021
Doc: DRX Installation
Version: 7.1 January 2021
DRX INSTALLATION MANUAL
DRX INSTALLATION MANUAL
APPENDIX A.5 RS-422-A
Connector
RS422-A
PIN
Function
1
2
3 4 5
6
7
8
9
Marker identifies pin 1.
View: Looking
into
the socket on the
DRX. Wiring view of cable side on plug.
1
PPS (AUX)
2
RxD B
3
RxD A
4
TxD B
5
TxD A
6
GND
7
8
9-32V+
9
9-32V-
Example Connection:
1
PPS (AUX)
PPS OUT
2
RxD B
TxD +
3
RxD A
TxD -
4
TxD B
RxD +
5
TxD A
RxD -
6
GND
PPS OUT GND
7
8
9-32V+
9
9-32V-
»
Isolation; Fully electrically isolated.
»
Cable; Multi core screened with tinned copper conductors.
»
Shield; Should be connected at far end.
NOTE: Depending on sensor compliance, this may be used as
direct NMEA 0183 input.
NOTE: Depending on equipment, Rx / Tx polarity may be labelled B and A
or + and -. This polarity must be maintained as per the example.
APPENDIX A.6 RS-422-B
Connector
RS422-B
PIN
Function
10
9
1
2
12
11
8
3
7
6
5
4
View: Looking
into
the socket on the
DRX. Wiring view of cable side on plug.
1
PPS (AUX)
2
RxD B
3
RxD A
4
TxD B
5
TxD A
6
GND
7
RESERVED
8
RESERVED
9
RESERVED
10
RESERVED
11
9-32V-
12
9-32V+
Example Connection:
1
PPS (AUX)
PPS OUT
2
RxD B
TxD +
3
RxD A
TxD -
4
TxD B
RxD+
5
TxD A
RxD -
6
GND
PPS OUT GND
7
RESERVED
8
RESERVED
9
RESERVED
10
RESERVED
11
9-32V-
12
9-32V+
»
Isolation; Fully electrically isolated.
»
Cable; Multi core screened with tinned copper conductors.
»
Shield; Should be connected at far end.
RS422B Internal DRX wiring of reserved pins is as follows:
RS422B Pin
RS422A pin
Function
7
2
RS422A RxB
8
3
RS422A RxA
9
1
RS422A PPS+
10
6
RS422A PPS-
NOTE: Depending on sensor compliance, this may be used as
direct NMEA 0183 input.
NOTE: Depending on equipment, Rx / Tx polarity may be labelled B and A
or + and -. This polarity must be maintained as per the example.