background image

4

   

Warner Electric • 800-825-9050

P-2105-WE    819-0549    5/17

Mounting

Enclosed Units

Any vertical, horizontal, or angled surface is  
suitable for mounting the CBC-300 and CBC-300-1 .

Follow these procedures to mount your control .

q

  1 . Remove the front cover by removing the top and 

bottom retaining screws .

q

  2 . Set the control on the mounting surface and mark 

for the three mountings holes in accordance with 
“Dimensions .” (See Figure 1)

q

  3 . Install the top two mounting bolts or screws until 

they are nearly flush, set the control over the larger 
top mounting holes and pull down to position the 
control .

q

  4 . Tighten the top bolts or screws and install the 

bottom bolt or screw and tighten .

This completes the mounting of the control . The control 
is now ready for final wiring . Refer to the wiring section 
for final wiring .

q

  1 . If the CBC-300-1 control is used, first pre-wire 

the external potentiometers . Refer to: External 
Potentiometer wiring for CBC-300-1, page 5

q

  2 . If the CBC-300 control is used, refer to: Final 

Wiring, page 6

SHORT

POWER

WARNER ELECTRIC

CLUTCH-BRAKE

CURRENT CONTROL

CBC-300-1

SHORT

POWER

WARNER ELECTRIC

CLUTCH-BRAKE

CURRENT CONTROL

CHANNEL 1

TORQUE ADJUSTMENT

CBC-300

1

2

3

4

5

6

7

8

9

10

0

CBC-300-1

CBC-300

4.460

(113.3) Max.

6.500

(165.1)

Max.

2.250

(57.2)

1.095

(27.81)

0.620

(15.75)

5.185

(131.7)

2.220

(56.39)

Ø0.180

(4.57)

Mounting

Ø0.375

(9.53)

(2 Plcs)

Ø0.180

(4.57) Slot

Mounting 2 Plcs

2.500

(63.5)

Max.

1.812

(46.02)

Max.

2.062

(52.4)

Max.

CHANNEL 2

1

2

3

4

5

6

7

8

9

10

0

(Figure 1)

Содержание CBC-300 Series

Страница 1: ...Installation Operating Instructions CBC 300 CBC 300 1 Series Dual Channel Adjust Clutch Brake Controls P 2105 WE 819 0549 An Altra Industrial Motion Company...

Страница 2: ...DIP switches located on the control s printed circuit board Two versions of the CBC 300 are provided to handle a wide range of applications The standard version is offered the same as before The CBC...

Страница 3: ...t a short circuit condition exists on one or both of the outputs Internal Adjustments Current Range Selection via DIP switches SW1 for Channel 1 and SW2 for Channel 2 Current Ranges Switch Setting 1 2...

Страница 4: ...stall the bottom bolt or screw and tighten This completes the mounting of the control The control is now ready for final wiring Refer to the wiring section for final wiring q 1 If the CBC 300 1 contro...

Страница 5: ...the accessory potentiometer kit is used wire the potentiometers per the colors as shown in the diagram q 3 Make sure all terminals are securely fastened and the wiring cable is secured so that it can...

Страница 6: ...ely q 2 Connect the other magnet either brake or clutch to Terminals 7 and 8 Tighten Terminal 7 securely q 3 Connect switching for Channel 1 to Terminals 5 and 6 Tighten both terminals securely q 4 Co...

Страница 7: ...n terminals securely q 5 Set DIP Switch SW1 for proper current setting before applying power to the control See Internal Switch Settings Chart for proper DIP Switch settings q 6 If external potentiome...

Страница 8: ...SF 120 EC 375 ATC 25 SF 500 ATC 115 Clutch Models SF 170 SF 250 SF 400 EC 475 EM 50 EM 100 EM 180 UM 50 UM 100 UM 180 UM 50C UM 180C EUM 50 EUM 100 EUM 180 PC 500 SF 825 PC 1000 SF 1225 PC 1225 PC 15...

Страница 9: ...Cause Solution External switching improperly wired Check wiring and switch connections and rewire if necessary Torque adjust set to zero 0 Set torque adjustment potentiometer to maximum level Current...

Страница 10: ...apply to you Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential...

Отзывы: