Warner Electric • 800-825-9050
P-2105-WE 819-0549 5/17
5
External Potentiometer wiring for CBC-300-1
q
1 . Remove the four screw that hold the bracket
assembly and PC Board to the chassis .
q
2 . Route the potentiometer cable(s) through one of
the conduit entrance holes on the bottom of the unit
and wire to the appropriate terminal block on the PC
board . Refer to the wiring diagrams below for the
proper connections .
CBC-300-1 External Current Limit Adjustment
q
1 . Wire the external current limit potentiometer to
Terminal Block TB-3 for Channel 1 and TB-4 for
Channel 2 as shown in the diagram . (See Figures 6
& 7)
q
2 . If the accessory potentiometer kit is used, wire
the potentiometers per the colors as shown in the
diagram .
q
3 . Make sure all terminals are securely fastened and
the wiring cable is secured so that it can’t pull loose
from the terminals .
This completes the preliminary wiring of the remote
potentiometers . The control is now ready for final wiring .
Refer to the wiring section for final wiring, page 6
Note:
Be careful not to pinch or crimp the pot wiring to
prevent shorting to the housing or components .
CBC-300-1
External Current
Limit Adjust
WHT
RED
BLK
CW
10K POT
10 FT MAX
10K, 2W POT
10% TOL, LINEAR OR
6011-101-002
ACCESSORY KIT (1)
CH1
TB3
3
2
1
TB-3
(Figure 6)
CBC-300-1
External Current
Limit Adjust
WHT
RED
BLK
CW
10K POT
10 FT MAX
10K, 2W POT
10% TOL, LINEAR OR
6011-101-002
ACCESSORY KIT (1)
CH2
TB4
3
2
1
TB-4
(Figure 7)