Contents

Introduction  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2
Specifications   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .3
Mounting  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .4
Electrical Connections  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .5, 6, 7
Internal Adjustments   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .8
Troubleshooting Checklist   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .9
Warranty   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Back Page

Failure to follow these instructions 

may result in product damage, equipment damage, 
and serious or fatal injury to personnel.

Introduction

Warner Electric’s CBC-300 and CBC-300-1 are constant 
current, solid state electronic power supplies designed 
to operate any of the Warner Electric 90 Volt clutches 
and brakes, including fail safe designs . They can operate 
a single clutch or brake, two clutches, two brakes, 
a combination clutch and brake, or a combination 
clutch and fail safe brake, depending on the switching 
arrangement used and the application requirements .

The CBC-300 series controls operate from 120 VAC 
single-phase input power . They provide constant current 
output as set by the torque adjustment potentiometers 
on the front panel or remote potentiometer . On the CBC-
300 series both outputs are adjustable . Output current 
ranges are selectable for the adjustable output channels 

in one of five ranges by the DIP switches located on the 
control’s printed circuit board .

Two versions of the CBC-300 are provided to handle 
a wide range of applications . The standard version 
is offered the same as before . The CBC-300-1 
version is available where an external limit adjustment 
potentiometers are required . 

Operations of both units are identical except for the 
method of the control potentiometer mounting . The 
CBC-300-1, external potentiometer option, has terminal 
blocks mounted on the PC boards for connection of the 
potentiometers .  

The potentiometers used can be supplied either as 
optional accessory items or be obtained from a local 
electronic supply house . 

An internal 1 .5A FA fuse is provided for line to ground 
shorts .

Two LED indicators are provided on the front panel of 
the control for “POWER” and “SHORT” indications . 
The green indicator marked “POWER” is illuminated 
whenever the AC input power is applied to the control . A 
red indicator marked “SHORT” is illuminated whenever 
a short circuit condition occurs in either of the outputs . 
To reset, power must be removed, the shorted condition 
cleared, and the AC input power reapplied to the control .

The enclosed version may be used with or without the 
cover . Removal of the plastic cover when the control 
is used in an enclosure will increase the operating 
temperature range of the control .

Содержание CBC-300 Series

Страница 1: ...Installation Operating Instructions CBC 300 CBC 300 1 Series Dual Channel Adjust Clutch Brake Controls P 2105 WE 819 0549 An Altra Industrial Motion Company...

Страница 2: ...DIP switches located on the control s printed circuit board Two versions of the CBC 300 are provided to handle a wide range of applications The standard version is offered the same as before The CBC...

Страница 3: ...t a short circuit condition exists on one or both of the outputs Internal Adjustments Current Range Selection via DIP switches SW1 for Channel 1 and SW2 for Channel 2 Current Ranges Switch Setting 1 2...

Страница 4: ...stall the bottom bolt or screw and tighten This completes the mounting of the control The control is now ready for final wiring Refer to the wiring section for final wiring q 1 If the CBC 300 1 contro...

Страница 5: ...the accessory potentiometer kit is used wire the potentiometers per the colors as shown in the diagram q 3 Make sure all terminals are securely fastened and the wiring cable is secured so that it can...

Страница 6: ...ely q 2 Connect the other magnet either brake or clutch to Terminals 7 and 8 Tighten Terminal 7 securely q 3 Connect switching for Channel 1 to Terminals 5 and 6 Tighten both terminals securely q 4 Co...

Страница 7: ...n terminals securely q 5 Set DIP Switch SW1 for proper current setting before applying power to the control See Internal Switch Settings Chart for proper DIP Switch settings q 6 If external potentiome...

Страница 8: ...SF 120 EC 375 ATC 25 SF 500 ATC 115 Clutch Models SF 170 SF 250 SF 400 EC 475 EM 50 EM 100 EM 180 UM 50 UM 100 UM 180 UM 50C UM 180C EUM 50 EUM 100 EUM 180 PC 500 SF 825 PC 1000 SF 1225 PC 1225 PC 15...

Страница 9: ...Cause Solution External switching improperly wired Check wiring and switch connections and rewire if necessary Torque adjust set to zero 0 Set torque adjustment potentiometer to maximum level Current...

Страница 10: ...apply to you Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential...