Internal Adjustments

The internal DIP Switch on the control circuit board adjusts the control for the proper current range to the clutch and/or 
brake coil being used . The Chart below indicates the proper setting based on coil resistance and Warner Electric product . 
To adjust for products not listed, obtain coil resistance information and set switches per coil resistance .

Switch DIP No.

1

2

3

4

5

Coil Resistance  
at 20° C (W)

1000-1550

350-999

250-349

205-249

100-204

Current Range

0 - 60 ma

0 - 175 ma

0 - 245 ma

0 - 305 ma

0 - 533 ma

Warner Electric

SF-120

EC-375

ATC-25

SF-500

ATC-115

Clutch Models

SF-170
SF-250
SF-400

EC-475

EM-50

EM-100
EM-180

UM-50

UM-100
UM-180

UM-50C

UM-180C

EUM-50

EUM-100
EUM-180

PC-500

SF-825

PC-1000

SF-1225

PC-1225
PC-1525
EC-1000

EM-210

UM-210
UM-215

UM-210C

EUM-210
EUM-215

SF-650

SF-825BM

PC-825

SF-1000

EC-650
EC-825

EC-1225

ATC-55

SF-1525

(Not SF-1525HT

 Models)

Warner Electric
Brake Models

PB-120
PB-170
PB-250
PB-400

EB-375
EB-475

EM-50

EM-100
EM-180

UM-50

UM-100
UM-180

UM-50C

UM-180C

EUM-50

EUM-100
EUM-180

ATB-25

PB-500
PB-650

PB-1000
PB-1225
PB-1525

EB-650

EB-1000
EB-1225

EMFB-50

UMFB-50

ER/FB-375

EM-210

UM-210
UM-215

UM-210C

EUM-210
EUM-215

EB-825

EMFB-180

UMFB-180

ER/FB-475

ATB-55
ER-825

EMFB-210

UMFB-210

ER/FB-650

ATB-115

Note:

 Only one switch number is to be set to the “on” position at any time .

Содержание CBC-300 Series

Страница 1: ...Installation Operating Instructions CBC 300 CBC 300 1 Series Dual Channel Adjust Clutch Brake Controls P 2105 WE 819 0549 An Altra Industrial Motion Company...

Страница 2: ...DIP switches located on the control s printed circuit board Two versions of the CBC 300 are provided to handle a wide range of applications The standard version is offered the same as before The CBC...

Страница 3: ...t a short circuit condition exists on one or both of the outputs Internal Adjustments Current Range Selection via DIP switches SW1 for Channel 1 and SW2 for Channel 2 Current Ranges Switch Setting 1 2...

Страница 4: ...stall the bottom bolt or screw and tighten This completes the mounting of the control The control is now ready for final wiring Refer to the wiring section for final wiring q 1 If the CBC 300 1 contro...

Страница 5: ...the accessory potentiometer kit is used wire the potentiometers per the colors as shown in the diagram q 3 Make sure all terminals are securely fastened and the wiring cable is secured so that it can...

Страница 6: ...ely q 2 Connect the other magnet either brake or clutch to Terminals 7 and 8 Tighten Terminal 7 securely q 3 Connect switching for Channel 1 to Terminals 5 and 6 Tighten both terminals securely q 4 Co...

Страница 7: ...n terminals securely q 5 Set DIP Switch SW1 for proper current setting before applying power to the control See Internal Switch Settings Chart for proper DIP Switch settings q 6 If external potentiome...

Страница 8: ...SF 120 EC 375 ATC 25 SF 500 ATC 115 Clutch Models SF 170 SF 250 SF 400 EC 475 EM 50 EM 100 EM 180 UM 50 UM 100 UM 180 UM 50C UM 180C EUM 50 EUM 100 EUM 180 PC 500 SF 825 PC 1000 SF 1225 PC 1225 PC 15...

Страница 9: ...Cause Solution External switching improperly wired Check wiring and switch connections and rewire if necessary Torque adjust set to zero 0 Set torque adjustment potentiometer to maximum level Current...

Страница 10: ...apply to you Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential...

Отзывы: