![background image](http://html1.mh-extra.com/html/warmflow/wah-100/wah-100_installation-and-servicing-manual_3405183021.webp)
4.2
Two Pipe Systems
0.5
35
100
0.5
30
100
1
25
100
1.5
20
90
Total Maximum Pipe Length (m)
2
15
70
3
8
30
3.5
6
20
I.D.
10 mm
I.D.
8 mm
Lift H
(m)
For maximum pipe length and lift contact de-aerator manufacturer.
STEEL TANK SHOWN
PLASTIC TANK ALSO SUITABLE
FIRE VALVE
FILTER
NON RETURN
VALVE
SAW CUT INSIDE
TANK TO PREVENT
SYPHON
FILTER MAY BE
POSITIONED
OUTSIDE
RETURN LINE
NO FILTERS OR VALVES
STEEL TANK SHOWN
PLASTIC TANK ALSO SUITABLE
FIRE VALVE
MAY BE POSITIONED
OUTSIDE
‘T’ TAP FOR DRAIN
DE AERATOR MAY
BE ABOVE OR
BELOW BURNER
FILTER
SHUT OFF VALVE
Must be upright
Page 19