3.7.2 RDB Burner Control Box
3.7.3 Fitting External Room Thermostat
CONTROL BOX
535SE/LD
M
M
Oil Valve
Photoresistance
Black
White
Blue
Motor
Capacitor
Lock Out
Live
Neutral
Earth
Fan
Housing
5
4
3
2
1
ROOM THERMOSTAT
REMOVE
LOOP ‘A’
MAIN THERMINAL BLOCK
6
7
8
9
3.7.4 Fitting a Frost Thermostat
The frost thermostat must be located in the coldest part of the building but where is
can respond to rise in temperature as a result of switching on the heater. A frost
thermostat should not be fitted on an outside wall.
The frost thermostat can be connected as per the room thermostat.