8.3.3 Sensor allocation
CAUTION
Changing these settings may impair the safety of the system or reduce its
effectiveness. Therefore, be sure that you are aware of the effects when you
make a change.
The sensors must be allocated to the channels for the control to function
properly. In doing so, you define how the sensors are used for controlling the
individual channels.
These variables are later evaluated by the safety and comfort functions when
triggering move commands and actions. Up to four measured "Photo" values
can be assigned per channel of the weather station 1; of these, the value
that is currently the highest is decisive. The photosensors are allocated to the
installation location as follows:
A
B
C
2
3
4
Fig. 20
Alignment of the photo diodes (example: weather station multisense)
The numbers 1 to 4 have been factory-assigned to the four photodiodes. (Po-
sition photodiode 1 to face northward as far as possible.) Position the photo-
diodes according to the building facades being shaded. It will be far easier
to allocate the photodiodes to the individual functions of the Wisotronic later
on if you connect the photodiodes to the Wisotronic according to their num-
bers. Additional information can be found in the sensor operating and instal-
lation instructions.
Pho
to
1
(Dawn/Dusk)
Pho
to
3
Photo 4
Photo 2
N
N
Channels
Содержание Wisotronic
Страница 1: ...Valid from 1st February 2022 warema_890558_alhb_en_v5 Installation instructions Wisotronic 1 channel...
Страница 105: ...warema_890558_alhb_en_v5 2022 02 01 We reserve the right to carry out improvements 105 Notes...
Страница 107: ...warema_890558_alhb_en_v5 2022 02 01 We reserve the right to carry out improvements 107 Notes...
Страница 108: ...WAREMA Renkhoff SE Hans Wilhelm Renkhoff Strasse 2 97828 Marktheidenfeld Main Germany http www warema de info warema de...