Introduction 

[M2001452_0] - EN / 22.06.12 

Page 4 of 20 

Subject to change without notice 

1.3

Important safety information 

The safety instructions and warnings described here are 
intended to safeguard your health as well as protect the 
product. Please read the following points 

carefully

Damage resulting from inappropriate use or the failure to 
observe these instructions or safety information is 

not

 

covered by the guarantee. Liability will 

not

 be accepted 

for secondary damage. 

General conditions 

If the external venetian blind with auxiliary motor and bat-
tery-operated emergency retraction set is used at 

escape 

doors

 and 

emergency windows

 to protect against sum-

mer heat and glare and to provide privacy, the battery-
operated emergency retraction set is activated in case of 
an emergency to 

clear the escape route

 

 

Correct functioning of the external veneti-
an blind with auxiliary motor and battery-
operated emergency retraction set and, 
therefore, unblocking of the escape doors 
and emergency windows in case of an 
emergency are only ensured if you follow 
our safety instructions closely. 

 
 

 

Danger to life and limb if the WAREMA 
control is not used! 

It must be ensured that the external venetian 
blind is 

only activated by the associated 

electronic battery-operated control

Mani-

pulations by third parties must be 
excluded

. It is important that the external 

venetian blind is 

not blocked

 by 

dirt

 or 

obstacles

 

 

 

Danger to life and product damage from 
incorrect procedure during commission-
ing!

 If the following points are not followed, 

no

 warranty can be granted for functional 

problems, soiling and damage. 

„

The external venetian blind must remain 
out of service until the commissioning has 
been  released. 

„

Raise the external venetian blind fully to 
clear the escape route. The external ve-
netian blind is sufficiently raised if the ex-
ternal venetian blind disappears into the 
cover panel (if present), or if the escape 
door or emergency window can be ope-
ned. 

 

Installation preparations 

 

 

Danger to life

 from restrictions of the escape 

route while during installation of the external 
venetian blind with auxiliary motor and bat-
tery-operated emergency retraction set! Befo-
re beginning installation, inform the safety 
officer that the escape route is available only 
to a limited extent. It must be ensured that the 
building can be evacuated along a different 
escape route. 

 
 

 

Risk of injury and damage to the product 
from incorrect installation!

 

„

Comply with the specified installation 
steps and instructions. 

„

Install the product only if it is in technically 
perfect condition. 

„

Before installation, check the mounting 
substructure to make sure it can bear the 
loads. 

„

Widely cordon off the installation site and 
the projection area of the external veneti-
an blind. 

 

Packaging 

 

 

Risk of suffocation!

 Do not leave the packa-

ging material lying around, and keep children 
away from small parts. Plastic film, polystyre-
ne, small parts, etc., can be very dangerous 
for children to play with. 

 

Electrical connection 

 

 

Electric shock from incorrect installation!

 

The electrical installation must be performed 
by a certified electrician in accordance with 
the electrical installation regulations published 
by the Association of German Electrical Engi-
neers (VDE 0100) or the standards and regu-
lations of the country in which the product is 
being installed. The specialist must observe 
the installation instructions included with the 
electrical appliances. Before commissioning 
the product, remove all lines that are not re-
quired. Disconnect any devices that are not 
needed for operation. 

 
 

Содержание External venetian blind

Страница 1: ...ternal venetian blind with auxiliary motor and battery operated emergency retraction set cable guidance Installation instructions For qualified technicians only Valid from 22 June 2012 Document no M2001452_0 EN ...

Страница 2: ...allation 9 3 1 Tools 9 3 2 Unpacking the external venetian blind 10 3 3 Scope of delivery 10 3 4 Marking the position of the external venetian blind 10 3 5 Mounting the bracket top rail bracket 11 3 6 Preparing the feedthrough for the power line 13 3 7 Attaching and centring the top rail 14 3 8 Securing the top rail 14 3 9 Overview of the fixation possibilities of the tension cable optional 15 3 1...

Страница 3: ...on Read and observe all warnings Please observe all safety installation operating and setting instructions Observe all warnings on the product 1 2 Explanation of symbols and signs Safety information and symbols are contained in the ap propriate parts of the text Symbol Use explanation DANGER Identifies an imminent danger that may result in death or serious injury if not pre vented WARNING Identifi...

Страница 4: ...missioning has been released Raise the external venetian blind fully to clear the escape route The external ve netian blind is sufficiently raised if the ex ternal venetian blind disappears into the cover panel if present or if the escape door or emergency window can be ope ned Installation preparations Danger to life from restrictions of the escape route while during installation of the external ...

Страница 5: ... and cause accidents 1 4 Information on the target group and ap plication of these instructions Target group These installation instructions are intended for quali fied fitters Knowledge of safety at work accident pre vention regulations working with ladders and scaffolding handling and transporting long and heavy items using fixation materials assessment of the building fabric commissioning and o...

Страница 6: ...xternal venetian blind Data for electric drive external venetian blind drive Parameter D339 Rated torque 9 Nm Power 131 W Current consumption 0 57 A Rated speed 26 rpm Rated voltage 230 V AC Frequency 50 Hz Degree of protection IP 54 Short term operation S2 4 minutes Limit switch range 97 revolutions Tab 2 Details on the external venetian blind drive NOTE The technical data on the control can be f...

Страница 7: ...ttery operated emergency retraction set can be activated reliably the external venetian blind must always be operated via the associated electronic bat tery operated control Additional loads on the external venetian blind with auxili ary motor and battery operated emergency retraction set such as from suspended objects could damage the pro duct or cause it to fall for example tearing of the liftin...

Страница 8: ...ill only meet the require ments of the stated wind speed limits when mounted if the recommended number of brackets holders and guides are mounted the instructions from the manufacturers for the dowels are followed When mounting on wood a wind speed limit cannot be given due to the variability of this building material 2 5 CE conformity CE conformity is certified and the corresponding EC dec larati...

Страница 9: ...tion of the cover panel the top rail must be protected from penetrating water At least two people are required for the instal lation NOTE Application drawings must be followed WARNING Risk of injury and falling Climbing aids must be positioned securely provide enough support and have a suffi ciently high load bearing capacity When working at great heights the approp riate provisions must be made t...

Страница 10: ...scope of delivery NOTE Check the scope of delivery using the delivery note Check the parts to make sure they are not damaged If any items are damaged or not as specified in the order stop the installation and contact WAREMA External venetian blind with auxiliary motor Tension cable bracket Instructions handover report Battery pack Fixing material Parts description n x Top rail bracket number depen...

Страница 11: ...orce per tension cable must be adhered to The fitter is responsible for the correct selection of fixing materials and adhering to the installation specifications of the fixing material manufacturer Mounting sub structure Fixation suggestion Concrete B15 Screw DIN 571 A2 6 x 60 Washer DIN 9021 A2 A6 4 Dowel S8 Aluminium PVC with steel core Screw DIN 7976 A2 6 3 x 38 Washer DIN 9021 A2 A6 4 Wood Scr...

Страница 12: ...t all dimension in mm Slat size L Number of top rail bra ckets brackets To 1300 mm 2 pieces To 2500 mm 3 pieces To 3500 mm 4 pieces Tab 7 Number of top rail brackets brackets depending on slat size NOTE For cover panels that will later be plastered on the front side we recommend additional brackets for stiffening Installing the brackets NOTE Only necessary for the attachment of a top rail bracket ...

Страница 13: ...es depending on the sub structure NOTE Check that the substructure is even by holding a suitable tool e g a spirit level against it and cor rect any unevenness Open the top rail bra ckets Attach the top rail bra cket to the substruc ture bracket using suitable fixing materials 3 6 Preparing the feedthrough for the power line WARNING Short circuit due to damage to the power line from unclean feedth...

Страница 14: ...1 1 Top rail 3 Screw DIN 7985 M 5 x 16 2 Top rail bracket 4 Screw DIN 7985 M 4 x 10 Fig 5 Attaching the top rail to the top rail brackets WARNING Risk of injury from falling blind Do not release the external venetian blind until the top rail brackets have been closed Lower the external venetian blind with the program ming cable by approx 600 mm Attach the top rail 1 to the top rail brackets 2 The ...

Страница 15: ... using the tension cable bracket tension cable hol der Marking the fixing points NOTE The tension cable must be perpendicular to the top rail The lower edge of the tension cable brackets must be approx 40 mm below the lower edge of the bottom rail when the external venetian blind is fully extended Slat size L Number of cable guidances To 3000 mm 2 pieces To 3500 mm 3 pieces Tab 9 Number of cable g...

Страница 16: ... tension cable Check the tension cable brackets to ensure they have the same height B and are parallel X1 X2 1 mm Measure diagonals D1 and D2 If D1 D2 the tension cables are parallel and at right angles Attaching the tension cable brackets NOTE Check whether the tension cable is conducted through the punched cable holes on all slats and on the bottom rail Mount the adjusting screw on the tension c...

Страница 17: ...e mar king properly aligned both vertically and hori zontally Transfer the fixing temp late of the tension cable bracket onto the mounting substructure NOTE Pencil in the fixing positions centrally to permit corrections later on Drill the fixing holes depending on the sub structure Attaching the tension cable brackets NOTE Check that the substructure is even by holding a suitable tool e g a spirit...

Страница 18: ...itions Do not adjust the upper limit position of the motor It is not permitted to change the fac tory setting The escape door could be blocked if it becomes impossible to raise the sun sha ding system Connect the programming cable to the plug in connector of the external venetian blind drive Check the limit positions of the external venetian blind by lowering and raising it multiple times NOTE In ...

Страница 19: ...n steps if neces sary Check the implementation of the installation steps that are needed for the reliable functioning of the ex ternal venetian blind with auxiliary motor and battery operated emergency retraction set against the follo wing checklists Installation step performed from these installation instructions P The motor lines are secured in such a way that they cannot come into contact with ...

Страница 20: ...ng the control can op tionally be set in such a way that the ex ternal venetian blind stays in the upper limit position and can no longer be lowered by the control or local operating elements We recommend the use of an ice monito ring system dd200001045 Fig 7 Attaching the label Notify the operator that the label should be applied in the area of the operating element Install and connect the batter...

Отзывы: