Hold the flash tube at the right and left side of the socket.
CAUTION!
Danger of cutting and splitting through breaking flash tube.
Just touch the flash tube in the range of the plug-in contact and not at
the levitated flash ring.
Agitate the flash tube carefully and pull out from the socket.
4.
Attach the new flash tube:
Place the two plug-in contacts of the flash tube loose into the socket.
Press the flash tube with even, slight pressure on the plug-in contacts
into the socket as far as it goes.
CAUTION!
Danger of cutting and splitting through breaking flash tube.
Put the pressure only on the range above the plug-in contacts and not on
the levitated ring flash.
ADVICE:
Press the two plug-in contacts carefully and even into the socket as to
avoid the deformation of the wires.
Hook in the retention clip with pliers.
Screw in modeling bulb.
See
Screw in and out of modeling bulb
.
Mount reflector.
See
Mount and demount reflector.
17.4.
Change micro-fuse
WARNING
Danger of electric shock and fire through short-circuit
A micro-fuse, which is not conform with the required specifications, doesn´t
protect against the overloading of the device.
Please just use a micro-fuse, which is conform with the required
specifications. See
Technical specifications
.
ADVICE:
The fuse holder keeps a spare fuse.
1.
Switch off device.
See
Switching on and off of device
.
2.
Disconnect from power supply:
Unplug power cord.
3.
Open fuse holder:
Use a small screwdriver to lift up the fuse holder carefully and slightly.
A
Fuse holder
4.
Pull out the fuse holder with your hands completely out of the slot.
5.
Take out the old micro-fuse.
6.
Take the new micro-fuse out of the spare slot and slide it in the center of
the holder.
7.
Slide the fuse holder carefully into the slot as far as it goes.
17.5.
Charge of flash capacitor
ADVICE:
Charge the flash capacitor completely,
when you have used the device several days mainly with reduced output
when you didn´t use the device for several months
Thus, you can protect the life expectancy of your flash capacitor and ensure a
continuous optimal power output.
1.
Switch on device.
See
Switching on and off of the device.
ADVICE:
The modeling lamp can remain switched off.
2.
Adjust maximal flash output:
Turn control OUTPUT POWER until the digital display OUTPUT POWER
shows the value 6.0.
3.
The device should remain switched on at least 30 min.
A
A
27
28