![WAGNER TOPFINISH DD10 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/wagner/topfinish-dd10/topfinish-dd10_operating-manual_868276026.webp)
26
VERSION 12/2017
ORDER NUMBER DOC 2366672
TOPFINISCH DD10
7.4
PRESSURE RELIEF/
WORK INTERRUPTION
The pressure must always be relieved:
− after the spraying tasks are finished.
− before servicing or repairing the system.
− before carrying out cleaning tasks on the system.
− before moving the system to another location.
− before something needs to be checked on the system.
− before the nozzle or the filter is removed from the spray gun.
The components for pressure relief on a CE-compliant spraying system include:
− Outlet equipment (return valve) mounted between pump and spray gun.
Process for relieving pressure
B_05380
2
3
4
5
7
6
8
1
1. Close the spray gun.
2. Close ball valve (2).
3. Release the system of pressure by opening the spray gun.
Attention: If a blocked nozzle is preventing relief, first carry out the additional steps
4 and 5, then clean the nozzle.
4. Close and secure the spray gun.
5. Open and close the return valve (3) slowly to completely depressurize the system.
Note:
Control air pressure is still present.
If the system has been used with 2K products:
NOTICE
Hardened working material in the spraying system when 2K product is processed!
Destruction of pump and injection system.
Follow the manufacturer‘s processing rules, particularly regarding the pot life.
Flush thoroughly before the end of the pot life.
The pot life is decreased by warmth.
Содержание TOPFINISH DD10
Страница 1: ...TOPFINISH DD10 Pneumatic Double Diaphragm Pump Version 12 2017 B_05369 B_06420 ...
Страница 2: ......
Страница 47: ......