![WAGNER TOPFINISH DD10 Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/wagner/topfinish-dd10/topfinish-dd10_operating-manual_868276023.webp)
23
VERSION 12/2017
ORDER NUMBER DOC 2366672
TOPFINISCH DD10
Grounding scheme (example)
B_05375
R max < 1 M
Ω
Pump
Product
Tank
Work piece
Conveyor
Spraying stand
Floor, static dissipative
Part / workstation
Cable cross section
Pump
4 mm2; AWG12
Paint tank
6 mm2; AWG10
Conveyor
16 mm2; AWG6
Booth
16 mm2; AWG6
Spraying stand
16 mm2; AWG6
Safe operation of the pump is only guaranteed with a grounding connection.
Connect all ground cables using a short and direct route.
B_05377
Procedure
1 Screw on grounding cable with eye.
2 Clamp the grounding cable clip to a grounding connection on site.
3 Ground the product (paint) tank to an on-site grounding connection.
4 Ground the other parts of the system to an on-site grounding
connection.
Ex zone
All devices and equipment must be suitable for use in potentially explosive areas.
All paints, flushing agents and waste tanks have to be electrically conductive.
All tanks must be grounded.