60
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
10.3 CHANGING VALVE
Procedure
1. Use a size 24 socket wrench to unscrew valve from
valve block.
2. Screw new valve into valve block and tighten with a
size 24 socket wrench.
10.4 REPLACING OPTICAL FIBER
B_06684
Procedure
1. Switch off high voltage.
2. Move reciprocator into cleaning position.
3. Switch off the reciprocator.
4. Thoroughly flush the high-speed rotary atomizer.
5. Set speed to "0" on controller.
6. Close all valves via the controller.
7. Unscrew front cover with hook wrench and remove it
8. Loosen Allen screws with a size 2 Allen wrench (see
photo).
9. Pull optical fiber cable to the rear and out off transition
piece.