45
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
be fed via the DM-valve.
For the conversion and/or retrofitting, the 1K mixing tube (order no. 2372283) is to be
replaced with the 2K mixing tube (order no. 2393711) with integrated static mixer.
As a wearing part, the static mixer can also be ordered separately and/or exchanged.
A continuous dosing of A and B is to be ensured. Also, the mixing ratio is to be ensured via
the dosing pump (via hardware) or via different rotation speeds by a controller. Flushing
must take place via the flushing valve before the respective dosing pump.
7.3.3 PRESSURE RELIEF/WORK INTERRUPTION
The pressure must always be relieved:
– when the spraying tasks are finished,
– before carrying out maintenance work on the spraying system,
– before carrying out cleaning tasks on the spraying system,
– before moving the spraying system to another location,
– if something must be checked on the spraying system,
– if the bell is removed from the high-speed rotary atomizer
The components for pressure relief on a CE-compliant spray system include:
– Air cock with pressure relief hole mounted between compressed air source and pneumatic pump.
– Product pressure relief valve mounted between pump and high-speed rotary atomizer.
Pressure Relief Procedure:
1. Switch off high voltage.
2. Deactivate valves in valve block via the controller.
3. Deactivate main needle valve.
4. Switch off steering airs SA1 and SA2.
5. Use stop air (STA) to set speed to "0".
A value between 50–100 rpm is shown in the controller display.
Notice
Always follow the procedure described above if pressure relief is specified in the instructions.
7.4
BASIC FLUSHING
Proceed in accordance with Chapter
Observe superordinate operating manual.
Regular flushing
The spray gun must be cleaned and flushed daily.
The cleaning and flushing agents used must be compatible with the working
material.
WARNING
Incompatibility of flushing / cleaning agent with the working medium!
Risk of explosion and danger of poisoning by toxic gases.
Examine the compatibility of the flushing and cleaning agents and working media
on the basis of the safety data sheets.