43
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
6.9.6 CALIBRATION
1. Remove front cover.
2. Lock spindle by pressing and holding locking button.
3. Remove bell plate with tool (see Chapter
).
4. Slide appropriate hose onto nozzle and guide into a suitable measuring cup.
5. Switch off steering airs SA1 and SA2.
6. Depending on the size of the measuring cup, discharge product for 1 minute or
twice for 30 seconds.
7. Compare the calculated application rate with the table.
8. If the application rate is too low, you may need to use a larger bell plate.
Notice
When calibrating with flushing agent, a volume of 500 ml in 1 minute may not be exceeded.
Adjust flushing agent pressure accordingly on pressure regulator.
6.9.7 VERIFYING A SAFE OPERATIONAL CONDITION
A skilled person must check to ensure that the device is in a reliable state after it is
installed and commissioned.
This includes:
– Carry out safety checks in accordance with Chapter
.