54
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
Location
Description
Inspection
interval
Type of
inspection
Inspection criteria
High-speed rotary
atomizer
Measure air pressure and
air volume at air inlet.
monthly
Measurement
Check whether the set values are
reached.
High-speed rotary
atomizer
Product valve
monthly
Visual inspection/
function check
Clean, check function and check
for leaks.
High-speed rotary
atomizer
Optical fiber
monthly
Visual inspection
Check for damage.
High-speed rotary
atomizer
Optical fiber
monthly
Visual inspection
Check for contamination.
High-speed rotary
atomizer
Product tube
contamination
monthly
Visual inspection
Check the product tube for
contamination.
High-speed rotary
atomizer
Check function of product
and flushing valves.
Six-monthly
Function test
Check whether the valves are
switching correctly.
High-speed rotary
atomizer
High voltage
weekly
Function test
Check actual and set values for
high voltage supply.
High-speed rotary
atomizer
HV cable
weekly
Visual inspection
Check for brittle points or black
spots.
High-speed rotary
atomizer
Speed control
monthly
Function test
Does the speed control quickly
control the speed?
Supply
Product supply lines
monthly
Visual inspection
Product supply lines not
damaged
Supply
Product supply lines
monthly
Visual inspection
Product supply lines not bent
Supply
Product supply lines
monthly
Visual inspection
Product supply lines not
interrupted
8.2.5.1 PRODUCT HOSES, PIPES AND COUPLINGS
The service life of the complete hoses between product pressure generator and application
device is reduced due to environmental influences even when handled correctly.
Check hoses, pipes, and couplings every day and replace if necessary.
Additionally, the operator must regularly check the complete hoses for wear and
tear as well as for damage at intervals that he/she has set. Records of these checks
must be kept.
The complete hose is to be replaced as soon as one of the two following intervals
has been exceeded:
– 6 years from the date of the hose crimping (see fitting embossing).
– 10 years from the date of the hose imprinting.
Fitting embossing
Meaning
xxx bar
Pressure
yymm
Crimping date (year/month)
XX
Internal code
Hose imprinting
Meaning
WAGNER
Name / Manufacturer
yymm
Date of manufacture (year/month)
xxx bar (xx MPa)
Pressure
e.g., 270 bar (27 MPa)
XX
Internal code
DNxx (e.g., DN10)
Nominal diameter