47
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
7.4.3 CHANGING CARRIER RING
B_06681
Procedure:
1. Unscrew union nut from air ring by hand or with hook
wrench and remove it.
2. Press and hold down locking button.
3. With locking button pressed and held, unscrew bell
plate.
4. Pull air control ring off carrier ring by turning slightly.
5. Loosen Allen screws on carrier ring and unscrew.
6. Pull off carrier ring.
7. Fit another carrier ring (tightening torque 1 Nm; 0.74 lb
ft).
8. Slide air control ring onto carrier ring.
9. With locking button pressed and held, screw on bell
plate and check for firm seating.
10. Slide union nut air ring up to stop and lock it with the
bayonet fitting.
There may be no gap at the rear of the union nut!
7.4.4 CHANGING PRODUCT NOZZLE
B_06681
Procedure:
1. Unscrew union nut from air ring by hand or with hook
wrench and remove it.
2. Press and hold down locking button.