![WAGNER Super Finish 21 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/wagner/super-finish-21/super-finish-21_operating-manual_3564741038.webp)
Super Finish 21 • 23
36
GB
Remedy in case of disturbance
Mounting
Place intake filter (3) with the long cone into the gun
1.
housing.
Screw in grip (2) into the gun housing and tighten.
2.
Slot in protective guard (1).
3.
Made in G
erman
y
max.
3900 psi
270 bar
G12
1
2
3
8.4
cleaninG airleSS Spray Gun
Rinse Airless spray gun with an appropriate cleaning agent.
•
Clean tip thoroughly with appropriate cleaning agent so that
•
no coating material residue remains.
Thoroughly clean the outside of the Airless spray gun.
•
Intake filter in Airless spray gun
dismounting (fig. 18)
Pull protective guard (1) forward vigorously.
1.
Screw grip (2) out of the gun housing.
2.
Remove intake filter (3).
Intake filter congested or defective – replace.
3.
9.
remedy in caSe oF diSturbance
type of malfunction
possible cause
Measure for elimination of mal-
function
unit does not start
No voltage.
•
Fuse protection has reacted. For
•
example an agitator is connected to
the socket on the unit. This agitator
has not been switched off before
switching on the unit Super Finish 21
or 23.
The unit switches off automatically in
•
case of overloading.
the unit does not switch on again
independently.
Check voltage supply
•
First switch on the unit Super finish 21 or
•
23 and then, for example, the connected
agitator.
Again after 2 - 3 minutes, switch unit on again.
•
unit does not exert suction
unit with suction system:
Filter extends beyond the liquid level
•
and sucks in air.
Suction filter congested.
•
Suction pipe not tightened, i.e. the unit
•
sucks in ancillary air.
device with upper hopper:
Filter disk congested.
•
Inlet valve is clogged, cannot be
•
pressed down into inlet valve housing.
Inlet valve does not close as, for example,
•
the guidance is clogged
Outlet valve is clogged
•
Refill coating material.
•
Clean or replace suction filter.
•
Clean and tighten connections.
•
Clean or replace filter disk.
•
Switch off unit. Inlet valve must allow
•
movement; test by pressing the inlet
valve slightly with a soft implement (e.g.
a pencil). Moving the inlet valve back and
forth removes impurities from the valve
seat. If this does not help, screw the inlet
valve out of the paint section and clean it,
refer to page 38, point 11.1.
Screw inlet valve out of the paint section
•
and clean, see page 38, point 11.1.
Screw the outlet valve out of the paint
•
section and clean, see page 38, point 11.2.
Содержание Super Finish 21
Страница 111: ...109 Super Finish 21 23...