Super Finish 21 • 23
34
GB
Interruption of work/ Cleaning unit
Close the relief valve, valve position
13.
(spraying).
Clean suction pipe for about three minutes.
14.
Rinse in circuit – open the relief valve, valve position
15.
(circulation).
Close spray gun.
16.
When cleaning with water, repeat procedure for about three
17.
minutes with clear water.
Switch off unit.
18.
Achtung
the effect of cleaning is increased if the
spray gun is alternately opened and closed.
Achtung
In case of coating materials diluted with
water, warm water improves cleaning.
•
unit with upper hopper
Switch on the unit.
1.
Turn pressure regulatin knob to the
2.
right
.
Close the relief valve, valve position
3.
(spraying).
Pull the trigger guard on the spray gun in order to pump
4.
residue coating material from the upper hopper, the high-
pressure hose and the spray gun into an open container.
Attention
In the case of coating materials containing sol-
vents, the container must be earthed.
Danger
caution! do not pump or spray in container
with a small opening (bunghole)!
See safety regulations.
Fill upper hopper with suitable cleaning agent.
5.
Open the relief valve, valve position
6.
(circulation).
Pump suitable cleaning agent in the circuit for several
7.
7.
InterruptIOn Of wOrk
Open the relief valve, valve position
1.
(circulation).
Switch off the unit.
2.
Pull trigger guard of spray gun to decrease the pressure
3.
of the highpressure hose and the spray gun.
Secure spray gun, see operating manual for spray gun.
4.
If the tip is to be cleaned, see page 46, point 13.2.
5.
6.
unit with suction system
Leave the suction system submerged in the coating
material or submerge it into the appropriate cleaning agent.
Suction filter and unit should not dry out.
Attention
In using quick-drying - or two-component
coating material, do not fail to rinse unit
through with a suitable cleaning agent during
the processing period.
8.
cleAnInG unIt (SHuttInG
dOwn OperAtIOn)
Cleanliness is the surest guarantee for disturbance-free opera-
tion. Always clean the unit after completing spraying work. In
no event may residue of the coating material dry and collect
in the unit. The cleaning agent used for cleaning (only with
a flash point of over 21 °C) must correspond to the coating
material.
Secure spray gun
•
, see operating manual for spray gun.
Dismount tip and clean, see page 46, point 13.2.
unit with suction system (fig. 14)
•
Remove suction system from the material vessel, e.g. put
1.
unit in the horizontal set-up position.
Switch on the unit.
2.
Turn pressure regulating knob to the
3.
right
.
Close the relief valve, valve position
4.
(spraying).
Pull the trigger guard on the spray gun in order to pump
5.
residue coating material from the suction pipe, the high-
pressure hose and the spray gun into an open container.
Attention
In case of coating material containing solvents,
the vessel must be earthed.
Danger
caution! do not pump or spray in container
with a small opening (bunghole)!
See safety regulations.
Submerge suction system in a suitable cleaning agent.
6.
Open the relief valve, valve position
7.
(circulation).
Switch off the unit.
8.
Screw on spray gun on suction pipe (fig. 14) with the two
9.
accompanying spanners 22 mm.
Switch on the unit.
10.
Pump suitable cleaning agent in the circuit for approx. 1
11.
minute.
Pull trigger guard on spray gun and hold with clamp.
12.
Содержание Super Finish 21