Contents, specifications and availability are subject to change without notice.
Tel. (860) 664-4911 • Fax. (860) 664-4912 • www.waecousa.com
WAECO USA, Inc.
7
Some experimentation may be necessary before the location of
the partition is finalized.
A minimum of 4” of rigid polyurethane
foam insulation is mandatory on all box surfaces for this
application. Please do not attempt it with less. In boxes up to 8
or 9 cubic feet, it is generally possible to obtain 2-3 cubic feet of
below-freezing space by creating a suitable partition.
For the partition, use a sheet of 2” rigid polyurethane foam core
with fiberglass or Formica faces, tightly fitted and sealed airtight
to the box sides and bottom. The necessary materials should be
available locally (home improvement outlets) and are relatively
easy to work with.
For cool air feed to the refrigerator side, drill a 3” diameter hole
halfway up the partition and leave about a 1” gap at the top. This
will allow for natural convection airflow from the freezer to the
refrigerator section.
You may need to install a manual damper over the hole to better
control individual compartment temperatures. This can be a
simple disc with a single pivot screw. As an alternative, you can
use the Adler/Barbour self-powered, thermostatically controlled
Automatic Shutter (Part #D7230). Use one automatic shutter for
each four cubic feet of refrigerator space. For the shutter, cut a
slot 1-1/8” high x 4” wide instead of a 3” hole.
For side door refrigerators, a Spillover Fan Kit #C7210 is
preferred—please see the following section.
Large Vertical
Evaporator
Optional: Owner installed 2” foamcore
insulated partition.
3” diameter adjustable opening in middle of
partition for cold air to refrigerator. Provide
a 10 sq. in. opening at top for air return.
Alternative location
for evaporator
Large Refrigeration or Combination Box—9–15 cubic feet total
OPTIONS:
• “All Refrigerator” without optional partition: provides ample
capacity for 3 ice trays (which are standard) and frozen food,
or
9 ice trays only and no frozen food.
• “Divided Refrigerator-Freezer” with customer-installed partition:
provides additional freezer capacity (up to approximately 3
cubic feet). Minimum 4” of insulation is mandatory, all surface
including lids and countertops.