BATTERY RECOMMENDATIONS

A minimum of THREE marine-grade batteries are strongly
recommended: One exclusively for engine starting and the other
two as a single bank for all other DC electrical devices such as
lights, electronics and your system. The second battery or group
of batteries (wired in series or parallel depending on voltage) is
commonly called the “house bank.” A standard marine battery
selector switch should be installed to isolate each battery or
battery bank.

The house bank should be at least 300 amp/hour capacity. More
is desirable. The larger the battery bank, the longer you can
operate the various loads between engine charging and the
faster you can recharge. This is because the alternator actual
output in amps is greater into a larger battery bank. Experts
suggest the bank’s nominal amp/hour rating should be four
times (4x) the alternator’s rated (hot) output.

The following ampere/hour capabilities are recommended for
the house bank, which serves the ColdMachine™.

For the “casual cruiser” 25-35 feet, seldom away from dock
for longer than overnight …minimum 200 amp/hours

For the “serious cruiser” 30-50 feet, often cruising for a week
or more …minimum 300 amp/hours

For the charter yacht or tropics-based “serious cruiser”
operating in hot climates and requiring  greater quantities of
ice cubes and frozen foods …. Minimum 400 amp/hours.

High Output Alternator, Electrical Management Systems, and
Batteries

The continuing proliferation of electrical and electronic devices
aboard boats has produced great interest in reducing engine-
running time required for battery charging. Specialty high-output
alternators are readily available. Several manufacturers offer
complete electrical generation and management systems. It is
now entirely practical for medium sized cruising boats to support
DC refrigeration, inverter-driven galley appliances, navigational
systems including computerized charting and radars, all with very
acceptable daily engine hours for battery charging.

As to batteries, a good deal of misinformation still exists
regarding “marine,” “deep-cycle” and “deep-discharge” batteries.
These terms generally describe a battery constructed to provide
small-to-moderate currents for long periods of time, as opposed
to short bursts of high current to start engines. While “deep-
cycle” batteries start engines quite satisfactorily, engine-starting
batteries are very poor for small current, long-term tasks.
Automotive, sealed, or so-called “maintenance-free” wet-type
batteries are okay for the engine start battery, but are not suitable
for the house or service battery bank that runs all the other
equipment on your boat 

regardless of how they are labeled. A

few manufacturers of genuine, marine, heavy-duty, deep cycle
wet-type batteries are creating a public awareness of the
inadequacies of disguised, re-labeled automotive batteries for
marine use, particularly as house batteries in sailing yachts.

GEL and AGM Batteries 

(as distinguished from so-called

“maintenance free” auto batteries ): Several high quality products
are available in all popular sizes. They perform comparably to the
very best wet-type deep cycle traditional batteries, but require
little or no maintenance. However they require very carefully
regulated charging systems, and cannot be simply interchanged
with wet batteries.

What all this means is that a boat owner with a full complement
of equipment aboard such as electronics, refrigeration, auto-pilot,
stereo, etc and who feels the engine must be run too long for
battery charging, can get very substantial improvements by using
the technology and equipment now available.

We strongly urge all boat owners to take advantage of the
excellent technical manuals, articles and products now available
in the marine industry. There is no longer any reason to put up
with long hours of engine running and marginal electrical
systems.

WIRING THE SYSTEM

All Adler/Barbour products from December 1998 forward
incorporate a new, more powerful and more energy efficient 
compressor featuring a 3-phase AC motor, which is driven and

digitally

managed by the 

electronic module

(the finned device

on the side of the compressor).

NOTE: The electronic module is not repairable, should not be
opened and must be replaced if damaged.

This control unit, like most electrical devices, requires fairly
“clean” DC current for stable operation and long service life.
Batteries provide clean, ripple-free DC current. Many battery
chargers, alternators and AC/DC converters may not. This means
that the ColdMachine should not be connected directly to any of
these devices, unless a battery is between them in the circuit.

Содержание ADLER /BARBOUR SERIES

Страница 1: ...e subject to change without notice Tel 860 664 4911 Fax 860 664 4912 www waecousa com WAECO USA Inc 1 WAECO USA Clinton CT www waecousa com Installation Operating Manual For ADLER BARBOUR SERIES ColdM...

Страница 2: ...Considerations 16 Water Cooled Optional Package Installation 17 Battery Recommendations 18 Wiring the System 18 Voltage Drops 19 Making the Power Connections 19 Wire Size and Wire Size Table 19 Wiring...

Страница 3: ...efficiency with minimal power consumption TERMINOLOGY Below are terms and definitions that will be used throughout this manual CONDENSING UNIT The stainless steel base plate mounted compressor electr...

Страница 4: ...ollowing points in mind when planning the installation GENERAL The connecting refrigerant tube set between the condensing unit and the freezer is 15 long 12 5 for PowerPlate Plan the location of the t...

Страница 5: ...ible location in the largest compartment available However many other locations are acceptable provided the appropriate ventilation duct kit is installed see below ENGINE COMPARTMENT DUCT KIT OR POWER...

Страница 6: ...TE The bracket may seem too light and flexible before it is mounted Once bolted securely to the bulkhead then use supplied bolts to secure the condensing unit base it becomes stabilized and very rigid...

Страница 7: ...You may need to install a manual damper over the hole to better control individual compartment temperatures This can be a simple disc with a single pivot screw As an alternative you can use the Adler...

Страница 8: ...up to 6 cubic feet with box insulation 4 or better 8 cubic feet with insulation of 6 or better REFRIGERATOR The standard small vertical or small horizontal evaporator is used for refrigerators up to...

Страница 9: ...keeps the tubing feeding smoothly without damaging it Be careful not to kink flatten or strain joints Make sure the plastic caps are in place over the refrigerant couplings Keep dirt out of the coupl...

Страница 10: ...he excess tubing and the thermostat wiring harness in an 18 to 24 diameter coil and secure preferably in a horizontal orientation Support the refrigerant tube set and the wire harness using clamps and...

Страница 11: ...away view of the male and female coupling halves being joined at 20 50 and 100 connection NOTE the way the cutter blades pierce the diaphragms and fold them back out of the flow path Also note the dif...

Страница 12: ...CW Clockwise the female until the coupling halves bottom out and strong resistance is felt THIS WILL REQUIRE ABOUT 6 FULL TURNS Work rapidly to minimize any possible escape of refrigerant past the tem...

Страница 13: ...hrough the thermostat flange holes INSTALLATION PROCEDURE see drawing below 1 Carefully unroll just enough capillary tubing to reach the metal and plastic clamp plates on the side of the freezer unit...

Страница 14: ...rovided MOUNTING THE TEMPERATURE SENSING BULB 1 Run the sensing bulb and wire into the refrigerated box to be controlled Mount the sensing bulb on a box side wall midway between top and bottom using t...

Страница 15: ...d now Do not allow any dirt sawdust foam insulation dust etc to get into couplings ends as this will seriously damage the system These couplings are different from the couplings that join the tube set...

Страница 16: ...he switch panel provided with this option note that the built in fan and the Powerduct fan if fitted continues to run This ensures a flow of air over the compressor to keep it relatively cool and is n...

Страница 17: ...d that the seacock is at least 2 below the waterline 5 Inlet thruhull must have a scoop facing forward on the outside of the hull to prevent back siphoning At high sailing speeds the flow direction ma...

Страница 18: ...a battery constructed to provide small to moderate currents for long periods of time as opposed to short bursts of high current to start engines While deep cycle batteries start engines quite satisfa...

Страница 19: ...breaker to prevent voltage drops in the supply circuit to the ColdMachine Also do not install voltage dropping devices such as indicator lights volt and amp meters etc in the 12 volt DC wiring circui...

Страница 20: ...20 WAECO USA Inc Tel 860 664 4911 Fax 860 664 4912 www waecousa com Contents specifications and availability are subject to change without notice...

Страница 21: ...Contents specifications and availability are subject to change without notice Tel 860 664 4911 Fax 860 664 4912 www waecousa com WAECO USA Inc 21...

Страница 22: ...22 WAECO USA Inc Tel 860 664 4911 Fax 860 664 4912 www waecousa com Contents specifications and availability are subject to change without notice...

Страница 23: ...Contents specifications and availability are subject to change without notice Tel 860 664 4911 Fax 860 664 4912 www waecousa com WAECO USA Inc 23...

Страница 24: ...thick frost formation is an indication of moist outside air entering through a poorly sealed lid doors or liner joints These conditions must be eliminated for proper performance The best way to defro...

Страница 25: ...at Do not set a positive differential Do not set a differential of 0 zero HIGH LOW SET POINT LIMITS HI LO Allow you to limit the range at which temperature set points can be programmed This is factory...

Страница 26: ...E FLASHING LED ON THE CONDENSING UNIT If the electronic module senses a malfunction it will auto matically switch into its protective mode and will make repeated start attempts at about 1 minute inter...

Страница 27: ...ressures Shut off power wait 15 minutes not yet equalized restore power Faulty electronic module Replace electronic module 3 Faulty compressor Call factory 5 Excessively hot electronic module Improve...

Страница 28: ...ing sleeve Partial clog in refrigerant circuit Call WAECO USA 860 664 4911 only part of the evaporator is frosting 3 Box insulation is inadequate or Re insulate Contact local dealer box too large for...

Страница 29: ...rtition between well insulated evaporator and perishable food section Thermostat sensing bulb not See manual correct mounted correctly Water pump runs no water flow Air in pump cannot self purge Check...

Страница 30: ...fins are soft and thin for maximum efficiency PROCEDURE FOR REMOVING EVAPORATOR AND TUBE SET 1 Turn the thermostatic control to OFF 2 Disconnect the 12V DC power supply to the compressor unit Carefull...

Страница 31: ...also have other rights which vary from State to State THERE ARE NO OTHER WARRANTIES OF MERCHANTABILITY FITNESS FOR PURPOSE OR ANY OTHER KIND ANY EXPRESSED OR IMPLIED ARE HEREBY DISCLAIMED AND EXCLUDED...

Страница 32: ...WAECO USA Inc P O Box 497 8 Heritage Park Road Clinton CT 06413 Tel 860 664 4911 Fax 860 664 4912 www waecousa com...

Отзывы: