![Wacker Neuson GPi 1700 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/wacker-neuson/gpi-1700/gpi-1700_operators-manual_3146045038.webp)
Maintenance
GPi 1700
wc_tx001235gb.fm
38
3.7
Cleaning the Fuel Filter
When
Clean the fuel filter monthly, or after every 200 hours of operation.
Prerequisite
Engine is stopped and cool to the touch
Description
The fuel filter
(g2)
is located beneath the fuel tank cap
(g1).
The fuel filter screen
removes sediment and other impurities from fuel added to the tank.
Procedure
Follow the procedure below to clean the fuel filter.
1. Lift the fuel tank cap cover
(g).
Unscrew and remove the fuel tank cap.
2. Remove the fuel filter from the fuel filling port
(g3)
.
3. Using fresh, clean water, rinse the fuel filter thoroughly. If necessary, use a clean
cloth or compressed air to remove residual sediment from the inside of the fuel
filter.
NOTICE:
Handle the fuel filter carefully to avoid damaging the screen. If the fuel
filter screen is torn or punctured, replace it.
4. Thoroughly dry the fuel filter, making sure that all water has been removed.
5. Re-insert the fuel filter into the fuel filling port.
6. Re-install the fuel tank cap, and close the fuel tank cap cover.
wc_gr006744
g
g1
g2
g3
Содержание GPi 1700
Страница 1: ...5000186370 04 0611 5 0 0 0 1 8 6 3 7 0 Operator s Manual Inverter Generator GPi 1700...
Страница 13: ...GPi 1700 Safety Information wc_si000347gb fm 13 1 6 Label Locations wc_gr006811 D E B H F G C A...
Страница 18: ...Operation GPi 1700 wc_tx001234gb fm 18 2 3 Features and Components l wc_gr006650 a b c f g n h m o l k i j d e...
Страница 39: ...GPi 1700 Maintenance wc_tx001235gb fm 39 Notes...
Страница 42: ...Schematic GPi 1700 wc_tx001236gb fm 42 4 Schematic A B J C D E F K Q P N O L M G H R wc_gr006649...
Страница 50: ......
Страница 51: ......