Control Panel
Pilot indicator
light (p)
The pilot indicator light illuminates when the generator is operating normally.
Overload
indicator light
(q)
The overload indicator light illuminates when the generator is operating in an
overload condition. An overload condition is defined as 120% of the available
power output of the generator.
After the indicator light has been illuminated for 20 seconds, an internal circuit
breaker will activate resulting in a no-load condition.
If the indicator light illuminates, stop and re-start the engine to clear the overload
condition and resume normal operation.
Oil sensor
indicator light
(r)
The oil sensor indicator light illuminates when the level of the engine oil falls below
the prescribed value. The engine stops automatically.
The engine cannot be re-started unless engine oil is added. Follow the
procedure described in
Adding Engine Oil.
wc_gr006445
p
q
r
s
t
u
v
w
x
y
CHOKE
Ref.
Description
Ref. Description
p
Pilot indicator light
u
GFI receptacle (120 VAC)
q
Overload indicator light
v
DC terminals
r
Oil sensor indicator light
w
DC circuit breaker
s
Auto power save indicator light
x
Ground lug
t
Auto power save switch
y
Engine switch
Содержание GPi 1700
Страница 1: ...5000186370 04 0611 5 0 0 0 1 8 6 3 7 0 Operator s Manual Inverter Generator GPi 1700...
Страница 13: ...GPi 1700 Safety Information wc_si000347gb fm 13 1 6 Label Locations wc_gr006811 D E B H F G C A...
Страница 18: ...Operation GPi 1700 wc_tx001234gb fm 18 2 3 Features and Components l wc_gr006650 a b c f g n h m o l k i j d e...
Страница 39: ...GPi 1700 Maintenance wc_tx001235gb fm 39 Notes...
Страница 42: ...Schematic GPi 1700 wc_tx001236gb fm 42 4 Schematic A B J C D E F K Q P N O L M G H R wc_gr006649...
Страница 50: ......
Страница 51: ......