GPi 1700

Operation

wc_tx001234gb.fm

17

2

Operation

2.1

Overview

Generator 
application

This generator is an exceptionally quiet, compact, and lightweight machine 
designed to provide single phase power for construction, commercial, and 
residential applications. State-of-the-art inverter technology ensures a consistent 
flow of clean and stable power suitable for operating not only tools, but also 
delicate electronic equipment.

Safety notices

„

Do not exceed the power output of the generator. Damage to tools or generator 
will occur. Refer to 

Technical Data

.

„

Do not exceed the rated current limit of any receptacle.

2.2

Preparing the Machine for First Use

Preparing for 
first use

To prepare your machine for first use:

1. Make sure all loose packaging materials have been removed from the machine.

2. Check the machine and its components for damage. If there is visible damage, 

do not operate the machine! Contact your Wacker Neuson dealer immediately 
for assistance.

3. Take inventory of all items included with the machine and verify that all loose 

components and fasteners are accounted for.

4. Attach component parts not already attached.

5. Add fluids as needed and applicable, including fuel, engine oil, and battery acid.

6. Move the machine to its operating location.

DANGER
Carbon monoxide.

 Using a generator indoors CAN KILL YOU IN MINUTES. 

Generator exhaust contains carbon monoxide (CO). This is a poison you cannot 
see or smell. If you can smell the generator exhaust, you are breathing CO. But 
even if you cannot smell the exhaust, you could be breathing CO.

f

NEVER use a generator inside homes, garages, crawlspaces, or other partly 
enclosed areas. Deadly levels of carbon monoxide can build up in these areas. 
Using a fan or opening windows and doors does NOT supply enough fresh air.

f

ONLY use a generator outside and far away from windows, doors, and vents. 
These openings can pull in generator exhaust.

f

Even when you use a generator correctly, CO may leak into the home. ALWAYS 
use a battery-powered or battery-backup CO alarm in the home.

f

If you start to feel sick, dizzy, or weak after the generator has been running, 
move to fresh air RIGHT AWAY. See a doctor. You could have carbon monoxide 
poison.

Содержание GPi 1700

Страница 1: ...5000186370 04 0611 5 0 0 0 1 8 6 3 7 0 Operator s Manual Inverter Generator GPi 1700...

Страница 2: ...distribution not authorized by Wacker Neuson Production Americas LLC represents an infringement of valid copyrights Violators will be prosecuted Trademarks All trademarks referenced in this manual are...

Страница 3: ...to make technical modifications even without notice which improve the performance or safety standards of its machines The information contained in this manual is based on machines manufactured up unti...

Страница 4: ...ifications are those that do not meet the approved criteria Unapproved parts attachments or modifications may have the following consequences Serious injury hazards to the operator and persons in the...

Страница 5: ...fting and Transporting 19 2 5 Installation 19 2 6 Power Requirements 20 2 7 Use of Extension Cords 21 2 8 Control Panel 22 2 9 Customer Connections 24 2 10 Grounding the Generator 25 2 11 Fueling the...

Страница 6: ...of Contents GPi 1700 6 4 Schematic 42 4 1 Schematic Components 43 5 Basic Troubleshooting 44 6 Technical Data 45 6 1 Engine 45 6 2 Generator Data 46 7 Emission Control Systems Information and Warrant...

Страница 7: ...personal hazards f Obey all safety messages that follow this symbol DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury f To avoid death or seriou...

Страница 8: ...quency requirements that are incompatible with the generator output Overloading the generator with a load that draws excessive power during either continuous running or start up Operating the generato...

Страница 9: ...ns carbon monoxide CO This is a poison you cannot see or smell If you can smell the generator exhaust you are breathing CO But even if you cannot smell the exhaust you could be breathing CO f NEVER us...

Страница 10: ...maged blades Operating safety To increase operating safety while running this machine Do not operate the generator when open containers of fuel paint or other flammable liquids are in the vicinity of...

Страница 11: ...g the generator Check the fuel lines and the fuel tank for leaks and cracks before starting the engine Do not run the machine if fuel leaks are present or the fuel lines are loose Do not run the engin...

Страница 12: ...cal regulations Personal injury avoidance Let the engine and muffler cool before transporting or servicing the machine Do not service the machine if your clothing or skin is wet Do not allow untrained...

Страница 13: ...GPi 1700 Safety Information wc_si000347gb fm 13 1 6 Label Locations wc_gr006811 D E B H F G C A...

Страница 14: ...se labels are described below Ref Label Definition A DANGER Using a generator indoors CAN KILL YOU IN MINUTES Generator exhaust contains carbon monoxide This is a poison you cannot see or smell NEVER...

Страница 15: ...et California EVP emission regulations for small off road engines E WARNING Improper connection of the generator to a building s electrical system can allow electrical current from the generator to ba...

Страница 16: ...rmation GPi 1700 wc_si000347gb fm 16 G WARNING Hot surface Do not touch DANGER Risk of carbon monoxide poisoning Keep a safe distance away from the machine H WARNING Hot surface Do not touch Ref Label...

Страница 17: ...ed with the machine and verify that all loose components and fasteners are accounted for 4 Attach component parts not already attached 5 Add fluids as needed and applicable including fuel engine oil a...

Страница 18: ...Operation GPi 1700 wc_tx001234gb fm 18 2 3 Features and Components l wc_gr006650 a b c f g n h m o l k i j d e...

Страница 19: ...generator to its operating location and then fill the fuel tank 2 5 Installation Locating the generator Follow the practices below when choosing an appropriate location for the generator Place the ge...

Страница 20: ...ired to keep it running The generator must be capable of supplying this surge current Other equipment may require more power than is actually stated on its nameplate Approximate startingpower requirem...

Страница 21: ...hart below as a guide for selecting proper cable size Use only extension cords rated for outdoor use and equipped with a third wire ground NOTICE Operating equipment at low voltage can cause it to ove...

Страница 22: ...on If the indicator light illuminates stop and re start the engine to clear the overload condition and resume normal operation Oil sensor indicator light r The oil sensor indicator light illuminates w...

Страница 23: ...eeds its limit or a malfunction occurs in a piece of equipment connected to the generator The DC circuit breaker has activated when the button pops out To reset the DC circuit breaker press the button...

Страница 24: ...ow the procedure below to test the GFI for proper operation every time the generator is used 1 Disconnect all equipment from the generator 2 Start the generator 3 Push the blue TEST button u1 on the r...

Страница 25: ...cal inspector or local agency having jurisdiction over electrical compliance If the generator is used at a construction site there may be additional regulations which must be observed In some areas ge...

Страница 26: ...Fuel tank capacity 3 5 L 0 92 gal Priming the fuel system When using the generator for the first time or if the fuel tank runs dry and the engine stops as a result the fuel system will require priming...

Страница 27: ...locked make sure that the generator is grounded to a good earthen ground per local regulations and NEC standards Internal and pre operation checks check engine oil and fuel levels fill as required det...

Страница 28: ...engine to run for 20 30 seconds and then turn the engine switch to the RUN position 5 Check to make sure that the pilot indicator light p is illuminated This indicates that the generator is operating...

Страница 29: ...e engine switch y in the RUN position while the machine is operating Connecting equipment 1 Insert the equipment plug into the 120V AC GFI receptacle u 2 Turn on the power switch for the equipment Dis...

Страница 30: ...on the generator to the positive battery terminal 2 Connect the negative terminal v2 black on the generator to the negative battery terminal 3 Charge the battery for the recommended length of time pre...

Страница 31: ...of the generator 2 16 Stopping the Generator Before stopping Check with other personnel on the jobsite and let them know that power is being turned off Make sure that the power shutdown will not creat...

Страница 32: ...ily Every 50 hours weekly Every 100 hours biweekly Every 200 hours monthly Every 500 hours Every 1000 hours Clean generator enclosure 3 Check for loose or missing fasteners 3 Check engine oil level an...

Страница 33: ...rom the oil fill port and check the oil level The oil level should fall between the upper and lower marks k1 k2 5 If the oil level is too low add oil until the level reaches the upper mark k1 6 Re ins...

Страница 34: ...e is covered with carbon deposits use a wire brush or spark plug cleaner to remove the carbon NOTICE If the spark plug is cracked or damaged replace it See Technical Data Checking the electrode gap 5...

Страница 35: ...rewdriver or a coin unscrew and remove the left side cover c from the generator enclosure 2 Lift and remove the air cleaner body cover d 3 Remove the foam insert d1 from the air cleaner body 4 Rinse t...

Страница 36: ...sure 3 Unscrew and remove the oil filler cap k with level gauge from the oil fill port 4 The oil drain plug k3 is located on the underside of the machine Remove the oil drain plug Drain the oil into a...

Страница 37: ...ster 1 Remove the four screws o1 from the rear cover o Remove the rear cover 2 Remove the fastening screw h1 from the exhaust outlet h Remove the spark arrester m 3 Use a stiff brush to remove carbon...

Страница 38: ...uel tank cap cover g Unscrew and remove the fuel tank cap 2 Remove the fuel filter from the fuel filling port g3 3 Using fresh clean water rinse the fuel filter thoroughly If necessary use a clean clo...

Страница 39: ...GPi 1700 Maintenance wc_tx001235gb fm 39 Notes...

Страница 40: ...see engine operator s manual Clean dry shop cloths Plastic cloth and containers of sufficient volume to collect drained fuel and oil Note Collect store and dispose of drained fuel and oil in accordanc...

Страница 41: ...e install the left side cover Change the engine oil See Changing the Engine Oil Check fasteners Check the machine for loose or missing fasteners Tighten or replace as needed Clean generator body 10 Us...

Страница 42: ...Schematic GPi 1700 wc_tx001236gb fm 42 4 Schematic A B J C D E F K Q P N O L M G H R wc_gr006649...

Страница 43: ...rminal D Ignition coil N Ground terminal E Pickup coil O Engine switch F Oil level sensor P Auto power save switch G Main coil Q AC receptacle H DC coil R Generator J LED indicator Wire Colors Blk Bla...

Страница 44: ...electrode 6 Add engine oil Engine power output is low 1 Air cleaner is dirty 2 Engine is overheated 1 Clean air cleaner 2 Consult engine owner s manual Engine stops 1 Engine malfunction 2 Fuel tank is...

Страница 45: ...er of cylinders 1 Displacement cm in 85 8 5 23 Engine speed rpm 3000 4200 Max rated power rated speed kW hp 2 1 2 82 4200 rpm Spark plug type NGK BM6A or BMR6A Electrode gap mm in 0 7 0 8 0 028 0 031...

Страница 46: ...Rated frequency Hz 60 Rated AC current A 11 3 Rated AC output KVA 1 35 Rated power factor 1 0 Rated DC voltage V 12 Rated DC current A 8 3 Safety device type Current breaker Grounding system Neutral...

Страница 47: ...presents cleaner exhaust from an engine The period of time in hours that the Air Index level is measured is known as the durability period Depending on the size of the engine a selection of time perio...

Страница 48: ...tes with high altitude areas Fuji will either pay for the shipping costs of replacement parts to and from an authorized service center Or Fuji will provides for a service technician to come to the own...

Страница 49: ...aintenance intervals IT IS ALSO NECESSARY FOR THE USER OF THIS GENERATOR TO CONDUCT THE MAINTENANCE AND ADJUSTMENTS ON THE EMISSION RELATED PARTS LISTED BELOW TO KEEP THE EMISSION CONTROL SYSTEM EFFEC...

Страница 50: ......

Страница 51: ......

Страница 52: ...cker Neuson Production Americas LLC N92W15000 Anthony Ave Menomonee Falls WI 53051 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Neuson Limited Room 1701 03 1717 20 17 F Tower 1 Grand Cent...

Отзывы: