OM EZ17 us 1.0 * ez17i400.fm
4-31
4
Start the engine
NOTICE
Damage to engine if it is started again immediately after stopping it.
►
Wait at least 10 seconds before starting the engine again.
NOTICE
Damage to preheater if the preheating system is operated too long.
►
Never preheat the engine more than 3 – 5 seconds.
1. Insert the starting key.
2. Turn the starting key to position
1
.
3. All indicator lights illuminate for 2 seconds.
➥
Replace malfunctioning indicator lights immediately.
4. Turn and hold the starting key in position
2
until indicator light
30
(preheating) goes out.
➥
Charge indicator light
28
illuminates.
➥
Indicator light
29
for the engine oil pressure illuminates.
5. Turn and hold the starting key in position
3
until the engine starts.
➥
All indicator lights go out.
➥
If the engine does not start after 10 seconds:
➥
Interrupt the start procedure and repeat it after about 1 minute.
➥
If the engine still does not start after a few tries: contact a Wacker
Neuson service center for error analysis.
6. As soon as the engine runs:
7. Release the starting key as soon as the engine runs.
Information
The engine will not start unless the control lever base is raised.
Warm-up phase of machine
After the engine has started, allow it to warm up at slightly increased idling
speed until it reaches its operating temperature of about 82 °C (180 °F)
(coolant).
Do not let the machine warm up at standstill.
During the warm-up phase, check for unusual noise, exhaust color, leaks,
malfunctions or damage.
In case of malfunctions, damage or leaks: park and secure the machine,
and find out the cause for the damage and have it repaired.
Fig. 70
0
1
2
3
P
Fig. 71
29
30
28
Содержание EZ17
Страница 12: ...1 6 OM EZ17 us 1 0 ez17v100 fm 1 Notes...
Страница 38: ...3 10 OM EZ17 us 1 0 ez17e300 fm 3 Warning labels Fig 11 symbolic representation...
Страница 43: ...OM EZ17 us 1 0 ez17e300 fm 3 15 3 Labels Fig 24 symbolic representation...
Страница 48: ...3 20 OM EZ17 us 1 0 ez17e300 fm 3 Notes...
Страница 66: ...4 18 OM EZ17 us 1 0 ez17i400 fm 4 Socket The machine is equpped with a 12 V socket on the right Fig 66...
Страница 138: ...5 56 OM EZ17 us 1 0 ez17b510 fm 5 Notes...
Страница 146: ...6 8 OM EZ17 us 1 0 ez17t600 fm 6...
Страница 198: ...7 52 OM EZ17 us 1 0 ez17w710 fm 7 Notes...
Страница 202: ...8 4 OM EZ17 us 1 0 ez17b800 fm 8 Notes...
Страница 222: ...9 20 OM EZ17 us 1 0 ez17t900 fm 9 Dimensions Overview EZ17 Fig 227...