![background image](http://html1.mh-extra.com/html/wacker-neuson/ez17/ez17_operators-manual_3134811149.webp)
OM EZ17 us 1.0 * ez17w700.fm
7-3
7
Information
Check the antifreeze at temperatures below 4 °C (39 °F).
Option
Check the load hook, joint rod, lifting eyes
7-51
Check the hydraulic quickhitch (Easy Lock) for damage
--
Check the Powertilt for damage
--
Weekly maintenance (every 50 service hours) (operator)
Page
Lubricate the machine according to the lubrication plan
7-6
Clean the lights/light system, signaling system, acoustic warning system
--
Check V-belt condition and tension
7-40
,
7-41
Option
Actuate Powertilt swivel device in final position for 1 minute
2
--
All steps for previous maintenance intervals
--
1.
Air filter replacement according to the dirt indicator, every 1000 s/h or once a year at the latest. (Replace after 50 s/h when in extensive use in environments
with acidic air, such as acid production facilities, steel and aluminium mills, chemical plants and other nonferrous-metal plants, independently of the dirt indi-
cator)
2.
Rinse the system to remove dirt. Repeat the procedure in the opposite flow direction.
Daily maintenance (operator)
Содержание EZ17
Страница 12: ...1 6 OM EZ17 us 1 0 ez17v100 fm 1 Notes...
Страница 38: ...3 10 OM EZ17 us 1 0 ez17e300 fm 3 Warning labels Fig 11 symbolic representation...
Страница 43: ...OM EZ17 us 1 0 ez17e300 fm 3 15 3 Labels Fig 24 symbolic representation...
Страница 48: ...3 20 OM EZ17 us 1 0 ez17e300 fm 3 Notes...
Страница 66: ...4 18 OM EZ17 us 1 0 ez17i400 fm 4 Socket The machine is equpped with a 12 V socket on the right Fig 66...
Страница 138: ...5 56 OM EZ17 us 1 0 ez17b510 fm 5 Notes...
Страница 146: ...6 8 OM EZ17 us 1 0 ez17t600 fm 6...
Страница 198: ...7 52 OM EZ17 us 1 0 ez17w710 fm 7 Notes...
Страница 202: ...8 4 OM EZ17 us 1 0 ez17b800 fm 8 Notes...
Страница 222: ...9 20 OM EZ17 us 1 0 ez17t900 fm 9 Dimensions Overview EZ17 Fig 227...
Страница 224: ...9 22 OM EZ17 us 1 0 ez17t900 fm 9 Notes...