PT 6 /...
Operation
wc_tx000261gb.fm
23
4.13 Strainer
NOTICE
:
DO NOT use a strainer with holes larger than the maximum
solid-size rating of the pump—50 mm (2 in.). DO NOT place the
strainer directly into mud or sand. Always keep the strainer suspended
in the liquid being pumped. Failure to follow the above directives may
cause pump damage.
4.14 Discharge Port
See Graphic: wc_gr001184
The discharge port
(a)
can be rotated 360° to direct water flow in any
direction.
To rotate the elbow:
4.14.1
Remove the locknuts
(b)
which hold the port to the pump housing.
4.14.2
Lift the port off the studs and position it as desired. Always check the
gasket and replace it if it is damaged.
4.14.3
Tighten the locknuts evenly. Torque them to 160 Nm (118 ft. lbs).