User manual - ZTA9648O - 41
I1 Up-I2 En/
Hol
H
I1 L
I2 HL
n + 2
n + 3
display value
n + 4
n +1
n
+1
+1
+1
+1
Counter count in Up
(increment) mode
derives from input
I1. Input I2 enables
updating of the counter
display or activates the
hold function of the
current counter value
I1 Down-I2
Off
H
I1 L
n - 4
n - 3
n - 2
n - 1
n
-1
-1
-1
-1
Counter count in Down
(decrement) mode
derives from input I1.
Input I2 remains free for
other uses
I1 Do-I2 En/
Loc
H
I1 L
I2 HL
n - 1
n - 3
n -2
n
-1
-1
-1
Counter count in Down
(decrement) mode
derives from input I1.
Input I2 enables or locks
(Lock) the counting