Out band
BAND
1
0
Activation
delay
Deactivation
delay
Auto
Logic Output
1
0
Latch
1
0
Pulse
Tach.
Value
BAND
Activation
delay
Deactivation
delay
Pulse duration time
Pulse duration time
Clear by Input
Clear by Input
Time
Tach.Value
SET
Output is active outside
a band defined by the
setpoint value and the
band.
117 Output duration
(Output Q1)
147 Output duration
(Output Q2)
177 Output duration
(Output Q3)
207 Output duration
(Output Q4)
Defines the output activation duration.
These parameters are visible only if the corresponding Source Value
parameter is set to Rate meter 1.
Automatic
(
Default
)
Output reset occurs automatically as soon as the
trigger condition fails.
Latch
Output, once activated, remains active until a Clear
command from appropriately configured digital
input.
0,1..99,9 s
Output once activated will be active for the set
time.
118 Activation delay
(Output Q1)
148 Activation delay
(Output Q2)
178 Activation delay
(Output Q3)
208 Activation delay
(Output Q4)
Defines the output activation delay.
These parameters are visible only if the corresponding Source Value
parameter is set to Rate meter 2.